The FMP10-40 Series are compact handheld devices for coating thickness measurement. There are three types available, Detlascope, Isoscope and Dualscope. They feature gauges that use the Magnetic Indcution Method or the Eddy Current Method depending on what is best suited for your needs. Requires a Fischer Probe, see Accessories below.
Certificate:
Features
Technical Attributes
Models: | Dualscope FMP20 | Dualscope FMP40 | Isoscope FMP10 | Isoscope FMP30 | Deltascope FMP0 |
Measurement Method: | Magnetic Induction, Eddy Current | Eddy Current | Magnetic Induction | ||
Applications: | Anodized coatings on aluminium (ISO/NF), Paint; varnish or plastic coatings on aluminium; copper or brass (ISO/NF), Paint; varnish or plastic coatings on steel or iron (ISO/FE), Zinc; chromium; copper coatings on steel or iron (NF/FE) | Anodized coatings on aluminium (ISO/NF), Paint; varnish or plastic coatings on aluminium; copper or brass (ISO/NF) | Paint; varnish or plastic coatings on steel or iron (ISO/FE), Zinc; chromium; copper coatings on steel or iron (NF/FE) | ||
Coatings: | Electrically Non-Conductive, Non-Ferrous Metals | Electrically Non-Conductive | Electrically Non-Conductive, Non-Ferrous Metals | ||
Base: | Ferromagnetic Metals, Non-Ferrous Metals | Non-Ferrous Metals | Ferromagnetic Metals | ||
Statistics: | Common values such as mean, standard deviation, coefficient of variation, min, max and range | Common values including mean, standard deviation, coefficient of variation, min, max and further definable parameters for V | Common values such as mean, standard deviation, min, max and range | Common values including mean, standard deviation, coefficient of variation, min, max and further definable parameters for block and final results | Common values such as mean, standard deviation, min, max and range |
Standards: | ASTM D7091, DIN EN ISO 2178, DIN EN ISO 2360 | ASTM D7091,DIN EN ISO 2178, DIN EN ISO 2360, IMO PCPC, QUALANOD, QUALICOAT, SSPC-PA2 | ASTM D7091, DIN EN ISO 2360 | ASTM D7091, DIN EN ISO 2360, IMO PCPC, QUALANOD, QUALICOAT, SSPC-PA2 | ASTM D7091, DIN EN ISO 2178 |
Mass: | 230 g | ||||
L x W x H: | 6.3" x 3.15" x 1.2" (160 x 80 x 30 mm) | ||||
Power Supply: | 4 AA Batteries or Rechargeable Battery Pack |
More Information
Magnetic Induction Method - The excitation current of the probe generates a low frequency magnetic field with a strength that is dependent on the coating thickness and is amplified by the magnetic base material. The signal of the measurement coil that captures this amplification is converted to the coating thickness reading by means of the probe characteristic stored in the instrument.
Eddy Current Method - The excitation current of the probe enerates a high frequency primary magnetic field that induces eddy currents in the base material. Its secondary magnetic field weakens the primary field. This weakening effect corresponds to the distance (= coating thickness) between the probe and the base material and is converted to the coating thickness reading by means of the probe characteristic stored in the instrument.
Standards
Delivery Content
Isoscope FMP30/Dualscope FMP40 - Price includes carrying case, operating instructions, shoulder strap, connection cable for FMP/PC, USB driver and battery set. Probes and calibration standards not included.
Isoscope FMP10/Deltascope FMP10/Dualscope FMP20 - Price includes operating instructions, shoulder strap, connection cable for FMP/PC, USB driver and battery set. Probes and calibration standards not included.
Accessories