Shyodu Gel Timer

Gel Timers

Art. No.: 11575

Standard Gel Timer 220v/50Hz

  • Standard Gel Timer
  • 220 V / 50 Hz

Select your Model

$995.00

Enter a value between 1 and 100000000 in increments of 1.

excl. taxes & shipping cost

  • Determines the gel time of resinous plastics, adhesives, drying oils and two component elastomers and paints
  • Simple device for a simple test - designed to produce gel time with accuracy at ambient or shop temperatures
  • No Frills, no cleanup
  • Uses inexpensive wire stirrers (10 stirrers included) and paper cups (not included)
  • No tools required
  • Designed to withstand hard use - put it out on the floor where the problems are
  • With a digital readout

Technical Data Chart
Data
Max. Recording Time:9999 min., 59 secs. (167 hrs.)
Min. Recording Time:1 second
Stir Speed:20 rpm
Accuracy:±2%
Electrical Requirements:(Specify) 110v/60Hz or 220v/ 50Hz 10w
Dimensions:7 1/2"L x 9"H x 5 1/2"W
Weight:4 lbs.
Electrical Connection:3-Wire Grounded Cord Set

Ambient Operating Conditions:

10°C-35°C or 50°F-95°F,  5 to 95% humidity (No condensing)
Standard Gel Timer 220v/50Hz

Manuals

Simple To Operate

  1. Pour the prepared material sample into the throwaway paper cup.
  2. Place the paper cup into the base of the unit by rotating the cup in the O-ring holder until seated completely.
  3. Insert the throwaway wire stirrer bottom into the cup and attach the top to the drive spindle, set the elapsed timer to “zero” and switch on the unit.
  4. When gelation occurs, read the time and discard the cup and stirrer.
  5. The Gel Timer gear motor can remain stalled for short periods without harm.

No Mess! No Tools Required! No Cleanup!

This durable gel timer uses inexpensive wire stirrers and paper cups. No special skills are required. Designed and constructed in the USA to offer long and useful laboratory or shop service.

  • A low torque synchronous motor rotates a specially shaped stirrer in the catalyzed resin or elastomer.
  • As gelation occurs, drag exceeds torque and the motor stalls.
  • Gel time can then be read on the LCD display.

Discover how to get accurate, repeatable gel time results with confidence. The article link blow provides the essentials of precision gelation measurement, why gel time matters, and how temperature control impacts results. - Precision Gelation Measurement

Paper Cups for Standard Gel Timers

Cups for Gel Timers 100/pk

Article No: 11572

Shyodu Gel Timer O Rings

Replacement Neoprene O Ring

Article No: 11573

Shyodu Gel Timer Display Replacement

Digital Display for New Shyodu Gel Timer

Article No: 11579

Wire Stirrers for Gel Timers

Wire Stirrers For Gel Timer 100/ pk

Article No: 11582

Shyodu Gel Timer Old Display Replacement

Digital Display for Old Shyodu Gel Timer

Article No: 15442

Shyodu Gel Timer

Standard Gel Timer 110v

Article No: 11574