Blue Spirit Thermometer F

Blue Spirit Thermometers

Art. No.: 15345

Spirit Thermometer, 0-120F

  • Spirit Thermometer
  • 0-120ºF

Select your Model

$108.00

Enter a value between 1 and 100000000 in increments of 1.

excl. taxes & shipping cost

  • ASTM approved high precsion lab thermometers
  • Non-mercury and Non-toxic
  • Eco and health-friendly 
  • Filled with easy to see blue spirits
  • Non-certified thermometers come with a Statement of traceability
  • Certified thermometers come with an ISO17025 Certificate that includes temperature points

Technical Data Chart
Data
Part No.1534215343153441534515346
Model No.:ACC017CBLSACC017FBLSACC001CBLSACC097FBLSACC009FBLS
ASTM No.:S17CS17FS1CS97FS9F
Name:Saybolt ViscositySaybolt ViscosityPartial ImmersionTankLow Pensky-Martens
Range:+19 to 27°C+66 to 80°F-20 to 150°C0 to 120°F+20 to 230°F
Divisions:0.1°C0.2°F1.0°C0.5°F1.0°F
Immersion:TOTALTOTAL76mmTOTAL57mm
Length:280mm280mm327mm305mm295mm
Certified No.:1534715348153491535015351
Cert Points*:21, 25C70, 77F-20, 0, 50, 100, 150C0, 32, 70, 110F32, 100, 160, 220F
*Certificates point come only with certified version of thermometer.
Spirit Thermometer, 0-120F
  • Statement of traceability

How to merge the interrupted indicator column when the liquid is located IN THE CONTRACTION CHAMBER

  1. Heat up your thermometer at the bottom receptacle (for example with a lighter).
  2. The indicator liquid must be pushed up carefully to the middle of the first expansion chamber in the process. 
    NOTE: Do not exceed this marking under any circumstances!
  3. Now tap lightly on the thermometer with your finger at the height of the first expansion chamber.
  4. The liquid should now have merged again.
  5. Repeat the procedure if necessary.

How to merge the interrupted indicator column when the liquid is located ABOVE THE FIRST EXPANSION CHAMBER

  1. Heat up your thermometer at the second expansion chamber (for example with a lighter).
    CAUTION: DO NOT EXCEED 200 °C!
    NOTE:
    This pushes the liquid downwards (into the cooler area).
  2. The indicator liquid must be pushed to about the beginning of the second expansion chamber in the process.
  3. Now please heat the thermometer at the bottom receptacle so that the filling liquid is pushed up again.
  4. The liquid should now have merged again.
    NOTE: Residues of the liquid may not remain above the chamber
  5. Repeat the procedure if necessary
    NOTE: Let the column cool down slowly in the case of thermometers with very narrow capillary openings!

How to eliminate a BLUE COLOUR FILM in the capillary

  1. Heat up the capillaries at the point where the colour film is located (for example with a lighter).
    CAUTION: DO NOT EXCEED 200 °C!
  2. Push the liquid column past the heated point.
  3. Subsequently let the liquid column cool down slowly.
  4. Repeat the procedure if necessary.

GENERAL NOTE: Draw special attention to thermometers with zero point. Please ensure that the column cools down slowly to avoid separation of the liquid.

IMPORTANT: The blue ACCU-SAFE liquid is non-toxic and eco-friendly. Should the thermometer break and emit the liquid, the liquid can simply be wiped up with a moist cloth and disposed of in the normal waste disposal.

Blue Spirit Thermometer C

Spirit Thermometer, -20 -150C

Article No: 15344

Blue Spirit Thermometer F

Spirit Thermometer, 66-80F

Article No: 15343

Blue Spirit Thermometer C

Spirit Thermometer, 19-27C

Article No: 15342

Blue Spirit Thermometer C

Certified Spirit Thermometer, 0-120F

Article No: 15350

Blue Spirit Thermometer C

Certified Spirit Thermometer, -20-150C

Article No: 15349

Blue Spirit Thermometer F

Certified Spirit Thermometer, 66-80F

Article No: 15348

Blue Spirit Thermometer C

Certified Spirit Thermometer, 19-27C

Article No: 15347

Blue Spirit Thermometer F

Spirit Thermometer, 20-230F

Article No: 15346

Blue Spirit Thermometer F

Certified Spirit Thermometer, 20-230F

Article No: 15351