Blue Spirit Thermometers
Spirit Thermometer, 0-120F
- Spirit Thermometer
- 0-120ºF
Select your Model
Enter a value between 1 and 100000000 in increments of 1.
excl. taxes & shipping cost
- ASTM approved high precsion lab thermometers
- Non-mercury and Non-toxic
- Eco and health-friendly
- Filled with easy to see blue spirits
- Non-certified thermometers come with a Statement of traceability
- Certified thermometers come with an ISO17025 Certificate that includes temperature points
| Technical Data Chart | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Data |
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
- Statement of traceability
How to merge the interrupted indicator column when the liquid is located IN THE CONTRACTION CHAMBER
- Heat up your thermometer at the bottom receptacle (for example with a lighter).
- The indicator liquid must be pushed up carefully to the middle of the first expansion chamber in the process.
NOTE: Do not exceed this marking under any circumstances! - Now tap lightly on the thermometer with your finger at the height of the first expansion chamber.
- The liquid should now have merged again.
- Repeat the procedure if necessary.
How to merge the interrupted indicator column when the liquid is located ABOVE THE FIRST EXPANSION CHAMBER
- Heat up your thermometer at the second expansion chamber (for example with a lighter).
CAUTION: DO NOT EXCEED 200 °C!
NOTE: This pushes the liquid downwards (into the cooler area). - The indicator liquid must be pushed to about the beginning of the second expansion chamber in the process.
- Now please heat the thermometer at the bottom receptacle so that the filling liquid is pushed up again.
- The liquid should now have merged again.
NOTE: Residues of the liquid may not remain above the chamber - Repeat the procedure if necessary
NOTE: Let the column cool down slowly in the case of thermometers with very narrow capillary openings!
How to eliminate a BLUE COLOUR FILM in the capillary
- Heat up the capillaries at the point where the colour film is located (for example with a lighter).
CAUTION: DO NOT EXCEED 200 °C! - Push the liquid column past the heated point.
- Subsequently let the liquid column cool down slowly.
- Repeat the procedure if necessary.
GENERAL NOTE: Draw special attention to thermometers with zero point. Please ensure that the column cools down slowly to avoid separation of the liquid.
IMPORTANT: The blue ACCU-SAFE liquid is non-toxic and eco-friendly. Should the thermometer break and emit the liquid, the liquid can simply be wiped up with a moist cloth and disposed of in the normal waste disposal.

Spirit Thermometer, -20 -150C
Article No: 15344

Spirit Thermometer, 66-80F
Article No: 15343

Spirit Thermometer, 19-27C
Article No: 15342

Certified Spirit Thermometer, 0-120F
Article No: 15350

Certified Spirit Thermometer, -20-150C
Article No: 15349

Certified Spirit Thermometer, 66-80F
Article No: 15348

Certified Spirit Thermometer, 19-27C
Article No: 15347

Spirit Thermometer, 20-230F
Article No: 15346

Certified Spirit Thermometer, 20-230F
Article No: 15351