Minimum Film Forming Temperature (MFFT)

Minimum Temperature Film Forming Bar (MFFT)

Art. No.: 15571

Minimum Temperature Film Forming Bar (MFFT)

The Rhopoint Minimum Film Forming Temperature Bar (MFFT) is a self-contained bench top instrument used to determine the minimum film forming temperature and white point in paint and coatings such as water base coatings, polymer dispersions, synthetic latexes, and emulsion.


Select your Model

$26,380.00

Enter a value between 1 and 100000000 in increments of 1.

excl. taxes & shipping cost

Minimum Film Forming Temperature (MFFT) is the lowest temperature at which a material forms a continuous film. The Rhopoint MFFT 90 provides a controlled temperature gradient across a nickel-plated copper platen, allowing operators to evaluate film formation across a range of temperatures in a single test.

Electronically controlled heating and cooling establish the selected temperature gradient, while built-in sensors monitor the platen temperature along its length. A hinged transparent cover provides thermal insulation and allows visual inspection of the sample throughout the test. Once the film-formation boundary is visible, the operator positions the cursor at that point and reads the corresponding temperature on the display.

  • Overall operating range of −10°C to 90°C (14°F to 194°F)
  • Ten preset temperature programs for different test ranges
  • Touchscreen controls with a built-in operating guide
  • Nickel-plated copper platen with electronically controlled heating and cooling
  • Built-in sensors monitor temperature along the platen
  • Movable cursor for identifying the film-formation boundary and reading its temperature
  • Hinged transparent cover for thermal insulation and visual observation
  • Audible and visual alarms warn of cooling-water supply failure
  • Supports testing in accordance with ASTM D2354 and ISO 2115.

Technical Data Chart
Data
Temperature range:−10°C to 90°C 
(14°F to 194°F)
Platen material:Dull nickel-plated copper
Platen dimensions 
(L × W):
483 mm × 235 mm 
(19 in  × 9.25 in)
Temperature sensing:Built-in sensors monitor temperature along the platen
Display:Touchscreen interface
Alarms:Audible and visual alarms for cooling-water supply failure
Power supply options:110–120 V AC or 220–240 V AC
Air supply:4 L/min at 100 psig
Cooling-water supply:Mains pressure; inlet temperature below 15°C (59°F), 
subject to the selected program’s cooling requirements
Water drain:Gravity 
MFFT Dimensions 
(H × W × D):
350 mm × 550 mm × 610 mm 
(13.78 in × 21.65 in × 24.02 in)
Weight:38 kg 
(84 lb)
Temperature Programs
Program0123456789
Cool end °C
 (°F)
-10
(14)
-5
(23)
0
(32)
5
(41)
15
(59)
23
(73)
33
(91)
43
(110)
53
(127)
63
(145)
Warm end °C 
(°F)
8
(45)
13
(55)
18
(64)
23
(73)
33
(91)
50
(122)
60
(140)
70
(158)
80
(176)
90
(194)

Cooling-water temperature must meet the requirements of the selected program. Program 0 requires supply water at 10°C (50°F) or below. An optional recirculating chiller is required if the available water supply cannot meet the selected program’s cooling requirements.
We need your approval
This content is provided by YouTube. By enabling this content, your personal data may be processed by the vendor and cookies may be set.
Accept
Cookie Banner powered by consentmanager.netconsentmanager.net

Manuals

Drying Time Recorder Cube Film Applicator

SS Applicator 75 & 150 Micron

Article No: 11346

Drying Time Recorder Cube Film Applicator

SS Applicator 50 & 100 Micron

Article No: 11348

Drierite Absorbent

Drierite Absorbent

Article No: 13313

MFFT Chiller

MFFT Chiller

Article No: 15572