Viscosity Oils
Art. No.: 13649
G100 Viscosity Oil w/Cert, 230 cS
- G100 Viscosity Oil
- With certification
- 230 centistokes
Download Excel Viscosity Chart HERE
Select your Model
Enter a value between 1 and 100000000 in increments of 1.
excl. taxes & shipping cost
- The G (Gardner) Series Viscosity Oils are certified viscosity reference standards used for the calibration Gardco Viscosity Cups, viscometers and rheometers. They facilitate accurate measuring for a variety of procedures associated with determining a fluid's resistance to flow.
- All oils come certified and traceable to NIST this document is the Certificate of Analysis, the Long Form certificate is an “Additional document” that supplements the traceability information that is described on the Certificate of Analysis.
- Oils with Long Form Certification include data points
- All Cannon Viscosity Oils are packaged in sealed, dark glass bottles. Net content of each bottle is 0.47 Liter (1 Pint)
- A label on each bottle gives the Viscosity Oil Name, Lot No., Termination Date, Viscosity in Centistokes at 25.00C (77.00F)* and a statement that the standard "is prepared expressly for Paul N. Gardner Co." by the Cannon Instrument Company and that data on the standard is traceable to the National Institute of Standards and Technology (NIST). *With the exception of the Parlin Cups whose Viscosity in Centistokes is measured at 23C in accordance with ASTM specification.
- A Material Safety Data Sheet (M.S.D.S.) accompanies each bottle of viscosity oil
- These viscosity oils prepared expressly by the Cannon Instrument Company for the Paul N. Gardner Company are produced in accordance with: ISO/IEC 17025, ISO 17025 and Guide 34 and ISO 9001. Viscosities for all standards sold by CANNON are based on the National Institute of Standards and Technology (NIST) value of 1.0016 mPa•s (centipoise) for water at 20°C (68°F).
- CANNON has been granted ISO 9002 registration for the manufacture and certification of viscosity standards.
- They are accurate to within 0.25% of the label value at specified temperature. This is a much closer tolerance than viscosity measuring devices normally available to users of viscosity cups. Therefore, there is no easy means of checking the viscosity to ensure that it remains at the value listed on the label except through very careful use of the standard to ensure its integrity. Included in this care should be making sure that any container used to receive the viscosity oil, as well as the cup to be checked, the thermometer and any other stirring device, be absolutely free of contaminants.
- Immediately following use, the standard should be returned to its labeled container and capped. If there is valid reason to question the original value of the viscosity standard, it should be replaced.
- The viscosity oils are used by the producer of Gardco viscosity cups not only to calibrate the cups but also to certify such calibration under ANSI/NCSL Z540 or ISO/IEC 17025, ISO 9001, as applicable, and in conformance with ISO 9000, which is available as an extra cost of service. One of the requirements under such certification is the replacement of the viscosity standard on or before the termination date. Experience has shown, however, that in the absence of contamination, the standards do not materially deteriorate over an extended period of time.
- CAUTION: Silicone fluids should not be used to calibrate viscosity cups. These materials change the interface between the cup surface and the test material and therefore change the cup calibration. The following is taken from ASTM D445; Viscometers used for silicone fluids should be reserved for the exclusive use of such fluids. Solvent washings from these viscometers should not be used for cleaning other viscometers.
| Technical Data Chart | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Data |
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Material Safety Data Sheet
Certificate of Analysis
Certificate of Analysis
Safety Instructions
- Cannon-MSDS-Viscosity-Oils-1.pdf
Cannon-MSDS-Viscosity-Oils-1.pdf

GJ3000P Viscosity Oil w/Long Form Cert
Article No: 14464

G100P Viscosity Oil w/Long Form Cert
Article No: 14462

G6 Viscosity Oil w/Long Form Cert
Article No: 14594

G20 Viscosity Oil w/Long Form Cert
Article No: 13643

G10 Viscosity Oil w/Cert, 19 cS
Article No: 13640

GJ3000P Viscosity Oil w/Cert, 10800 cS
Article No: 13656

G6 Viscosity Oil w/Cert, 9 cS
Article No: 13639

G350 Viscosity Oil w/Long Form Cert
Article No: 13654

G60 Viscosity Oil w/Long Form Cert
Article No: 13647

G350P Viscosity Oil w/Cert, 810 cS
Article No: 13655

G200 Viscosity Oil w/Cert, 450 cS
Article No: 13651

G35 Viscosity Oil w/Cert, 64 cS
Article No: 13644

G200 Viscosity Oil w/Long Form Cert
Article No: 13652

G20 Viscosity Oil w/Cert, 34 cS
Article No: 13642

G350 Viscosity Oil w/Cert, 880 cS
Article No: 13653

G60 Viscosity Oil w/Cert, 120 cS
Article No: 13646

G10 Viscosity Oil w/Long Form Cert
Article No: 13641

G100 Viscosity Oil w/Long Form Cert
Article No: 13650

G100P Viscosity Oil w/Cert, 270 cS
Article No: 13648

G35 Viscosity Oil w/Long Form Cert
Article No: 13645

G350P Viscosity Oil w/Long Form Cert
Article No: 14463
