Melting Point MP200D

SMP Series Melting Point Apparatus

Art. No.: 15105

Digital Melting Point Meter, 240VAC

  • MP-200D Melting Point Apparatus (previously SMP10)
  • Maximum temperature of 300°C with 1°C resolution
  • 2°C/min ramp rate after initial warm-up
  • 240V

Select your Model

$1,495.00

Enter a value between 1 and 100000000 in increments of 1.

excl. taxes & shipping cost

  • No need for fragile glass thermometers—temperature is fully digital
  • Select, measure, and display temperature digitally for accurate, repeatable results
  • Easily view the melt through a magnifying lens with built‑in illumination
  • Be more productive by testing two samples simultaneously
  • Save time with a programmable plateau temperature for rapid initial warm‑up
  • After warm‑up, the unit heats slowly to the melt temperature for greater accuracy, with flexible temperature adjustment options depending on the model
  • Designed for maximum safety and ease of use in routine or teaching labs
  • Extendible back feet let you set the optimal viewing angle and improve operator comfort

Technical Data Chart
Data
Part No.:1510513296
Description:Standard resolution (MP-200D)High resolution (MP-200D-HR-120)
No. of Samples:2
Temperature Range:Ambient to 300°C
Temperature Resolution:1°C0.1°C
Temperature Accuracy:±1.0°C to 20°C
±2.5°C at 300°C
Display:Three digit LEDFour digit LED
Temperature Sensor:100Ω Pt RTD
Ramp Rates:20°C per minute to plateau
2°C per minute to melt
20°C per minute to plateau
between 1 and 10°C per minute
Voltage:240V120V
Manual Languages:English, German, French, Spanish
Dimensions W x D x H (mm):160 x 220 x 170 mm
Net Weight:1.8 kg
Digital Melting Point Meter, 240VAC

MP-200-D Melting Point Apparatus (240V)
Pack of 100 glass capillary tubes (open at one end)
Power cord

Manuals

  1. Select a plateau temperature on the digital display (about 10 °C below the expected melting point), then press “Start”.
  2. The block heats rapidly to the plateau (about 20 °C/min) and holds at that temperature until you are ready to test.
  3. Insert the prepared sample tubes into the block and press “Start” again to begin the measurement.
  4. The unit heats at a fixed rate of 2 °C/min for the MP‑200D (previously SMP10) or at a user‑selected rate of 1–10 °C/min for the MP‑200D‑HR-120 (previously SMP20).
  5. When the sample is seen to melt, note the temperature on the display and press “Stop” to end heating and allow the block to cool.

For detailed instructions and safety information, see the full manual in the Downloads tab.

SMP Melting Point Capillary Tubes

Capillary Melting Tubes 100/pk

Article No: 13297

Digital Melting Point Apparatus MP200D-HR-120 Front

Digital Melting Point Meter, Hi-Res, 120 VAC

Article No: 13296