Ultracycle Drying Time Recorder

Gardco Ultracycle RHT Drying Time Recorder

Art. No.: 11325

Ultracycle Drying Time Recorder

  • Ultracycle RHT Circular Drying Time Recorder
  • Has relative humidity and temperature measurement
  • Programmable timing cycle within range from 1 minute to 99 hours, 59 minutes

Trade-in your old Drying Time Recorder and receive a 20% discount on a new one. Call for more information 954-946-9454.

Select your Model

$1,596.00

Enter a value between 1 and 100000000 in increments of 1.

excl. taxes & shipping cost

  • Designed to control a motor so that its shaft driven 3/8" teflon stylus will complete one rotation in a period which can be programmed from 1 minute to 99 hours, 59 minutes. 
  • Can be used directly on any substrate
  • Microprocessor controlled crystal timing regulation
  • Vastly improved tracking definition
  • Status and Time event count-up displayed on a 16 character LCD
  • Ambient temperature sensor switchable °F or °C with min., max. & current temperature displayed
  • Relative humidity with min, max
  • Auto stop upon completion of time cycle
  • Power failure indicator
  • 100-240V 50/60Hz
  • Accuracy RH: ±3% typical, Temperature: ±0.3°C typical
  • Meets Standard Test Methods for Drying, Curing, or Film Formation of Organic Coatings ASTM D1640/D1640M-14.
  • Made by the Paul N. Gardner Co. Teflon® is the registered trademark of E.I. DuPont de Nemours & Co., Inc.
  • CE/UL/UKAS/CSA Approved

Technical Data Chart
Data
Ambient Operating Conditions:32°F to 120°F (0-50°C), 5 to 95% humidity (No condensing)
Warranty:1 Year
Shipping Weight:7 lbs
ASTM
D5895
D1640
D711
ISO
9117-4
Ultracycle Drying Time Recorder

Manuals

Learn more about the function, use and perks of the Ultracycle Circular Drying Time Recorder from this article.

Attach the arm and ball assembly to the motor shaft by way of the hex screw. Once tightened to the desired position do not forcefully move the arm and ball position without loosening as this can cause damage for the gearbox assembly.

Apply the coating to your test panel using a Gardco Microm Film applicator or equivalent wet film applicator. Immediately place the Drying time recorder on your test panel and lower the clean 3/8 in. weighted Teflon stylus gently into position. Select the desired drying time and the stylus will then begin to be drawn along the test panel. After the selected time cycle is complete the Drying time recorder will automatically stop.

Evaluate the test panel using the supplied Time Template to determine the stages of drying time. Place the clear Time Template over the circular area scribed by stylus and note appropriate scale number of minutes or hours required for the film to cure, the character of the track by the 3/8 in. Teflon ball stylus relate to the drying of the film (Reference ASTM D5895). Record the results and if desired, record the temperature, humidity and the wet film thickness as these factors are important in considering the drying time of films.

  1. Press On, the Green LED will energize
  2. Press Menu key to enter
  3. Set hours by pressing the Scroll key
  4. Press Menu key to enter
  5. Set Minutes by pressing the Scroll key
  6. Press Menu key to enter
  7. Select Fahrenheit or Centigrade with the Scroll key
  8. Press Menu key to enter
  9. Press Start
  10. DT-5022 will stop upon completion of time cycle
Drying Time Recorder Power Supply

Power Supply w/Plug Kit, 12 vDC

Article No: 14530

Drying Time Recorder Counterbalance Weight

Counter Weight Replacement

Article No: 15008

Drying Time Recorder 12 gram Weight

12 Gram Weight

Article No: 15009

Ultracycle Drying Time Recorder Template

Ultracycle Template Replacement

Article No: 15010

DTR Stylus shaft and 3/8" Nylon Ball

Article No: 15543