Bresle Salt Contamination Detection Kit
Bresle Patch Salt Kit with Exstik Meter
- Bresle Patch Salt Kit
- ExStik II EC500 waterproof pH and conductivity meter, measures conductivity, TDS, Salinity, pH and Temperature using one electrode
Select your Model
Enter a value between 1 and 100000000 in increments of 1.
excl. taxes & shipping cost
The Bresle Salt Contamination Detection Kit is a conductometric determination of soluble salt contamination. It is essential that the level of contaminants on a surface is measured prior to coating in order to ensure the quality of the coating and that its optimum lifetime is achieved. If the coating is applied to a contaminated surface which is not properly prepared, it could fail prematurely resulting in costly re-coating and high maintenance costs. This is why the Bresle Salt Contamination Detection Kit is so important.
- Reliable and accurate
- It is easy to use and portable
- In accordance with ISO 8502-6 and ISO/DIS 8502-9
- Can prevent costly repair and need for recoating
- Box of 25 Bresle Patches
- Disp. Beaker 30ML Grad.
- Syringe/NDL 10cc 21G 1"
- Exstik
- Bottle 500ML Distilled Water
- Pair of Gloves
Manuals
- Bresle-Salt-Contamination-Detection-Kit-Manual.pdf
Bresle-Salt-Contamination-Detection-Kit-Manual.pdf
Many inspectors have to test surfaces in accordance with ISO 8502-6 and ISO/DIS 8502-9, which specify tests using the Bresle Patch as the method of extracting the soluble salts from the test surfaces.
- The Bresle Patch is adhered to the test surface and distilled water is pumped into the patch using a syringe.
- The water is pumped between the patch and the substrate, which causes the soluble salts on the test surface to be dissolved into the water.

Syringe and Needle 10cc 21G 1"
Article No: 10848

Rectangular Bottle 500ml Distilled Water
Article No: 10849

Disposable PP Beaker 30ml Graduated
Article No: 10850

Bresle Patches 25/pk
Article No: 10892

EC500 Cond/pH/TDS Meter
Article No: 15336