Software smart-process COLOR for spectro2guide spectrophotometer from BYK-Gardner shows standard management

Color & Jetness measurement with digital standards

Art. No.: 7087

spectro2guide Pro 45/0
Close-tolerance 45/0 spectrophotometer for deepest black

  • Color control as you see it with 45/0 circumferential geometry
  • 60° gloss measurement
  • Color control for fluorescent and non-fluorescent samples
  • Jetness measurement of deep black colors
  • Outstanding technical performance for use of digital standards
  • Professional data analysis with smart-chart software

Select your Model

$19,020.00

Enter a value between 1 and 100000000 in increments of 1.

excl. taxes & shipping cost

How black is black really?
Black has been and still is one of the most popular colors. In the development of black colors, the depth is objectively evaluated with the Jetness index based on colorimetric data. spectro2guide Pro was enhanced to measure deepest blacks with highest accuracy.

  • Improved accuracy to measure Jetness of deep black colors
  • Color, gloss and new fluorescence measurement in one
  • Exchange of digital standards between members of spectro2family and even with color2view benchtop
  • Balanced and upfront design with large color touchscreen
  • Smart docking station with intelligent auto diagnosis to tell you when to calibrate
  • Live preview of the measurement spot with integrated camera
  • Smart high-tech LED illumination for excellent short-term, long-term and temperature stability
  • 10 year warranty on LED light source - no lamp change needed
  • Professional data analysis with smart-chart combined with WiFi or USB data transfer

Color Measurement
Color Geometry45°c:0°
Sample Port12 mm
Measuring Area8 mm
Spectral Range Colorimetric400 - 700 nm, 10 nm resolution
Spectral Range Fluorescence340 - 760 nm, 10 nm resolution
Measurement Range0 - 170% reflection
Repeatability Color0.01 ΔE94 (10 consecutive measurements on white)
Reproducibility Color0.1 ΔE94 (average of 12 BCRA II tiles)
Color SystemsCIELab/Ch, Lab(h), XYZ, Yxy
Color DifferencesΔE*; ΔE(h); ΔECMC; ΔE94; ΔE99; ΔE2000; E2000 PF; ΔE DIN6175-2019
Color IndicesYIE313, YID1925, WIE313, CIE, Berger, Color Strength, Opacity, Metamerism, Grayscale
IlluminantsA, C, D50, D55, D65, D75, F2, F6, F7, F8, F10, F11, UL30, CIE 015:2018 LED Illuminants
Observer2°, 10°
Fluorescent IndicesΔE Fl, ΔEzero
Jetness IndicesMY, Mc, dM, GY, Gc, dG
Repeatability JetnessY ≤ ± 0.0005
Reproducibility JetnessY ≤ ± 0.003 (Y<0.5)
Technical Specifications
Measuring CapabilityColor, Gloss, Fluroescence, Jetness
General
Memory4.000 Standards and 10.000 Samples
InterfaceUSB port
Display3.5 " Color Touchscreen
LanguagesEnglish,German,French,Italian,Spanish,Russian,Japanese,Chinese
Power supplyInternal rechargeable battery
Power supply100 - 240 V, 50/60 Hz
Battery7.2 V, 2350 mAh, 16.92 Wh
Battery Capacity1200 readings
Weight0.7 kg
Weight1.5 lb
Operating temperature10 - 40 °C
Storing temperature0 - 60 °C
Operating temperature50 - 104 °F
Storing temperature32 - 140 °F
Relative humidityUp to 85 % non-condensing at 35 °C (95 °F)
Dimensions: L x W x H8.7 x 11 x 18.8 cm
Dimensions: L x W x H3.4 x 4.3 x 7.4 in
Gloss Measurement
Repeatability Gloss 0-20± 0,1 GU
Repeatability Gloss 20-100± 0,2 GU
Reproducibility Gloss 0-20± 0,5 GU
Reproducibility Gloss 20-100± 1,0 GU
Gloss Geometry60°
Gloss Aperture5 x 10 mm
Measurement Range Gloss0 - 100 GU
We need your approval
This content is provided by YouTube. By enabling this content, your personal data may be processed by the vendor and cookies may be set.
Accept
Cookie Banner powered by consentmanager.netconsentmanager.net
Spectrophotometer
Docking station with built-in diagnosis standard
White calibration standard
Color and gloss test standard
Grey calibration standard for Jetness
Black color standard for Jetness testing
Certificate
2 smart-chart licenses for download
USB to connect docking station to PC (7077)
USB cable for data transfer (7078)
LED flashlight to check cleanness
Stylus (7079), Protective cap (7076), hand strap
Manual, Carrying case
1-day training

Manuals

Short Instructions

Safety Instructions

Brochure

Adapter-Rings for Sample Holder Round Dish - M

Adapter Rings for 4453, 6415, 6468, 6806

Article No: 6416

Lipstick Kit for sample holder cosmetics for BYK-mac i multiangle spectrophotometer

Lipstick Kit

Article No: 6461

Nail Kit for sample holder cosmetics for BYK-mac i multiangle spectrophotometer

Nail Kit

Article No: 6462

Nail attachement for nail kit m1

Nail Attachment for 6462

Article No: 6463

Cylinder Kit for sample holder cosmetics for BYK-mac i multiangle spectrophotometer

Cylinder Kit

Article No: 6464

Wet Drawdown Template - C2

Article No: 6467

Sample Holder Round Dish - C2

Article No: 6468

Sample holder cosmetics for BYK-mac i multiangle spectrophotometer, OPEN

Sample Holder Cosmetics

Article No: 6469

Positioning Adapter for spectro2guide spectrophotometer from BYK-Gardner

Positioning Adapter for spectro2

Article No: 7073

Protective cap for spectro2guide spectrophotometer from BYK-Gardner m1

Protective Cap, spectro2guide

Article No: 7076

USB Interface cable for spectro2guide spectrophotometer from BYK-Gardner

USB Interface Cable, spectro2guide

Article No: 7077

Online cable for spectro2guide spectrophotometer from BYK-Gardner

Online Cable for spectro2 and 7300

Article No: 7078

Stylus for spectro2guide spectrophotometer from BYK-Gardner

Stylus, spectro2guide

Article No: 7079

Docking station for spectro2guide spectrophotometer from BYK-Gardner m1

Docking station for spectro2guide

Article No: 7080