Features
Technical Attributes
Models: | Imperial | Metric | Digital |
Measurement Type: | Mils | Microns | Mils/Microns |
Measurement Range: | 0-0.250” | 0-6.35mm | 0.00005" (0.001mm) |
Side Plate Options: | Aluminum (Standard) or Teflon (Tefcrom) | ||
Blade Options: | Stainless Steel (Standard) or Teflon | ||
Locking Mechanism: | - | - | Included |
Display: | Analog | Analog | Digital Display |
Procedure
Before use, check the zero settings of the micrometers. Place applicator on a polished granite flat plate or alternatively plate-glass of suitable size. Set micrometers at zero. The blade should touch the glass/granite flat plate from end to end without the side plate being elevated. When the applicator is placed between the observer and a bright back light the user should see no light from beneath the blade and side plates. The zero point should check within ± 0.0005". If not press the Zero button on the digital micrometer to reset the reading to zero. Repeat if necessary to assure a proper zero is achieved. Cautionary Note: Make sure that there is no foreign matter such as iron fillings adhering to the blade magnets as this might result in improper applicator calibration.