+1 (954) 946-9454

Rapid Flash Point Tester

Article No. 11447

Flash Point Tester Closed 316SS

The Rapid Tester® is a semiautomatic instrument for determining the flash point temperature / combustibility of flammable liquids. Closed cup test temperatures from ambient to 572°F (300°C) are automatically controlled by the set-a-temp adjustable digitally preset target temperature circuitry. Integral digital LCD display, NIST traceable thermometer, and electronic timer are standard.

Select your model

$6,197.00 excl. taxes & shipping cost

Features

  • Achieve the high level of digital performance
  • With better than 99% comparability you can use the Rapid Tester® with confidence.
  • The high contrast LCD display has 1/2" characters for ease of reading and is switch selectable between degrees Fahrenheit and Centigrade
  • A thermometer traceable to the National Institute of Standards & Technology is also included
  • Test time is only one minute with a 2 ml sample for flash points below 212°F (100°C). You can run ten tests with the Rapid Tester® in the time that it takes to perform just one by other methods. The 2 ml/4 ml sample is a fraction of the large sample required by other flash point methods. This reduces sampling and disposal problems while improving safety.
  • The Rapid Tester is great for:
    • Quality Assurance - Verify the formulation of liquid products with flammable ingredients.
    • Compliance Testing - Often required by regulatory agencies before transport or disposal of liquids
    • Fuel Dilution - Determine the relative percentage of fuel in engine crank case oil to forecast the need for engine rebuilding.
  • Independent laboratory testing has demonstrated that the ASTM D3828 test method utilized by the Rapid Tester® correlates well with other flash point methods. In ASTM D-2 Round Robin testing it was found that the ASTM D3828 test method has the following correlation coefficients:
    • D3828 (Rapid Tester®) vs. D56 (Tag) = 0.9949
    • D3828 (Rapid Tester® vs. D93 (Pensky-Martens) = 0.9943
    • D56 vs. D93 = 0.9926

Technical Attributes

  • Data
    Part No.11443114441144611447
    Cup Type:Closed Cup
    Temperature:-22° to 572°F (-30° to 300°C)
    Material:Aluminum Test Cup, Lid & Shutter316 Stainless Steel Test Cup, Lid & Shutter
    Adapter Voltage:External Gas Adapter 220VExternal Gas Adapter 110VExternal Gas Adapter 220VExternal Gas Adapter 110V

More Information

Warranty - Rapid Tester instrumentation is warranted against defects in materials and workmanship for one year from date of shipment and will be repaired or replaced at our option. This warranty is exclusive of shipping charges, consumable components or misuse. The liability of Gardco is limited to such repair or replacement. No warranty of fitness for a particular purpose or liability for consequential or other damages shall be implied.


Note: This contains only a general description of the Rapid Flash Point Tester. While uses and performance capabilities are described, under no circumstances should the product be used except by qualified, trained personnel and not until the instructions, labels, or other literature accompanying it have been carefully read and understood and the precautions therein set forth followed. Only they contain the complete and detailed information concerning this product. Not intended for use in hazardous areas. The manufacturer reserves the right to alter design and/or specifications without notice. Please note that butane cylinders in Rapid Tester holders must be constructed of black acetyl plastic to retrofit,

Standards

ASTM D3278

ASTM D3828

ASTM D4206

BS 3900 Part A11

BS 3900 Part A13

BS 3900 Part A14

CPSC CFR 16-1500.43a

DOT CFR 49-173.115

IATA Resolution 618 Attachment A

IP 303

ISO 3679

ISO 3680

OSHA 29CFR 1910-106

OSHA 29CFR 1910-1200

Procedure

  1. Unique set-a-temp circuitry permits simple adjustment and precise automatic regulation of test temperatures.
  2. Depress the Preset switch while turning the Temperature Control knob until the target temperature is displayed.
  3. Release the switch and set-a-temp takes over!
  4. Test cup temperature is automatically shown on the digital LCD display.

Delivery Content

Integral digital LCD display, NIST traceable thermometer, electronic timer, syringe, heat transfer compound, AC cord and directions.

Accessories

11449
Heat Transfer Compound Sm Packet
$48.00
11450
Metal Cooling Block (Rt-05500)
$332.00
11451
Refrig Charged Cooling Block
$823.00
11452
Syringe 2ml/4ml (Rt-05520)
$177.00
11453
316 SS Lid &Shut Assy Repl(Rt-14880-600)
$1,128.00
11455
Silicone Gas Tubing Repl Per Foot
$18.00
11457
Black Anodized Metal Lid&Shttr Assy Repl
$933.00
11459
Gasket High Temp Graph 14983
$39.00
11460
Fuel Cylinder Valve
$178.00
15146
External Gas Adapter kit forRapid Tester
$139.95
Join our Email List. subscribe