Rapid Flash Point Tester
Flash Point Tester -22/572F Closed 220v
The Rapid Tester® is a semiautomatic instrument for determining the flash point temperature / combustibility of flammable liquids. Closed cup test temperatures from ambient to 572°F (300°C) are automatically controlled by the set-a-temp adjustable digitally preset target temperature circuitry. Integral digital LCD display, NIST traceable thermometer, and electronic timer are standard.
Select your Model
Enter a value between 1 and 100000000 in increments of 1.
excl. taxes & shipping cost
- Achieve high level of digital performance, better than 99% comparability
- High contrast LCD display has 1/2" characters for ease of reading
- Switch selectable between degrees Fahrenheit and Centigrade
- Includes External Gas Adapter, (optional ISO-Butane Fuel Canister available)
- A thermometer traceable to the National Institute of Standards & Technology is also included
- Test time is only one minute with a 2 ml sample for flash points below 212°F (100°C)
- Run ten tests with the Rapid Tester® in the time that it takes to perform just one by other methods
- The 2 ml/4 ml sample is a fraction of the large sample required by other flash point methods which reduces sampling and disposal problems while improving safety
- Quality Assurance - Verify the formulation of liquid products with flammable ingredients
- Compliance Testing - Often required by regulatory agencies before transport or disposal of liquid
- Fuel Dilution - Determine the relative percentage of fuel in engine crank case oil to forecast the need for engine rebuilding.
- Independent laboratory testing has demonstrated that the ASTM D3828 test method utilized by the Rapid Tester® correlates well with other flash point methods. In ASTM D-2 Round Robin testing it was found that the ASTM D3828 test method has the following correlation coefficients:
- D3828 (Rapid Tester®) vs. D56 (Tag) = 0.9949
- D3828 (Rapid Tester® vs. D93 (Pensky-Martens) = 0.9943
- D56 vs. D93 = 0.9926
- Meets CPSC CFR 16-1500.43a / DOT CFR 49-173.115 / IP 303
Warranty - Rapid Tester instrumentation is warranted against defects in materials and workmanship for one year from date of shipment and will be repaired or replaced at our option. This warranty is exclusive of shipping charges, consumable components or misuse. The liability of Gardco is limited to such repair or replacement. No warranty of fitness for a particular purpose or liability for consequential or other damages shall be implied.
| Technical Data Chart | ||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Data |
| |||||||||||||||||||||||||
| ASTM | D3278 D3828 D4206 |
|---|---|
| BS | 3900-A11 3900-A13 3900-A14 |
| ISO | 3679 3680 |
| OSHA | 1910-106 1910-1200 |
- Integral digital LCD display
- External Gas Adapter
- NIST traceable thermometer
- Electronic timer
- Syringe
- Heat transfer compound
- AC cord
- Instructions
Manuals
- Rapid-Flash-Point-Tester-Manual.pdf
Rapid-Flash-Point-Tester-Manual.pdf
- Unique set-a-temp circuitry permits simple adjustment and precise automatic regulation of test temperatures.
- Depress the Preset switch while turning the Temperature Control knob until the target temperature is displayed.
- Release the switch and set-a-temp takes over!
- Test cup temperature is automatically shown on the digital LCD display.

Heat Transfer Compound Sm Packet
Article No: 11449

Metal Cooling Block (Rt-05500)
Article No: 11450

Refrig Charged Cooling Block
Article No: 11451

Syringe 2ml/4ml (Rt-05520)
Article No: 11452

316 SS Lid &Shut Assy Repl(Rt-14880-600)
Article No: 11453
Silicone Gas Tubing Repl Per Foot
Article No: 11455

Black Anodized Metal Lid&Shttr Assy Repl
Article No: 11457

Gasket High Temp Graph 14983
Article No: 11459

Fuel Cylinder Valve
Article No: 11460

External Gas Adapter Kit Rapid Tester
Article No: 15146

Low Range Thermometer 32°-230°F/0°-110°C
Article No: 15281

High Range Thermometer 212-450F/100-250C
Article No: 15282

Isobutane Fuel Canister (4 Pack)
Article No: 15529

Flash Point Tester Closed 316SS 220v
Article No: 11446

Flash Point Tester -22/572F w/Ext Gas
Article No: 11444

Flash Point Tester Closed 316SS
Article No: 11447