The Corrosion Test Chamber can be used for Salt Fog, CASS, Humidity, Water Fog and many other test methods. They are easy to use and operate, and designed to provide the accuracy and flexibility necessary to meet today's demanding test methods.
Features
Double wall, water jacketed design for accurate temperature control and stability.
Oven cured, continuous polymer coated interior for maximum durability.
Available in sizes ranging from 9.3 cu. ft. to 2,508 cu. ft.
Clear acrylic cover allows for full view of test specimens.
Opti-Fog™ - Patented fog generation tower with internal baffling per ASTM B117.
They perform a wide range of accelerated corrosion tests including, but not limited to: ASTM B117; ASTM B368 (CASS); ASTM D1735; ASTM D2247 1; ISO 9227; DIN 50027; ASTM G85 (A1) (A2) 2 (A3) 2 (A4) 2 (1 Humidity Test Packages for Condensing Humidity Tests - 2 Multi Test Control Package for Static Temperature Cyclic Tests)
Saturates incoming air supply with humidity to ensure accurate and stable operation. Low water sensor system for heater protection.
Individual temperature controls with selectable °C or °F units
Exposure zone dry bulb
Exposure zone wet bulb
Humidifying tower
Precision air regulator assembly
4” Certified Pressure Gauge, 0-30 psi
Air flow meter, 0-50 scfh
Level-MaticTM or DI-FIll Solution Reservoirs
Level-Matic™ - 10-gallon DI water and 24-gallon solution reservoirs with patented Level-Matic™ level control.
DI-FIll - Direct connection to existing plant DI water supply, includes 55-gallon solution reservoir with stand.
Calibration traceable to NIST
Salt Fog Start Up Kit - with (2) 80cm2 condensate collection assemblies, (1) 50lb bag of salt, (1) specific gravity hydrometer, (1) package of five PTFE filter cloths, (2) support racks, (2) support bars, (1) 15-30° specimen tray and (1) operation manual.
Technical Attributes
Exposure Zone: | Ambient to 120°F (±3°) / or 50°C (±2°) | ||
Humidifying Tower: | Ambient to 140°F (±3°) / or 60°C (±2°) | ||
Humidity: | 95-100% | ||
Fog Rate: | 1-3 ml/hr | ||
Supply Air Pressure: | 40-120 psi maximum | ||
Supply Air Volume: | 40-50 scfh @ 12-18 psi | ||
Drain: | 1/2” NPT | ||
Exhaust: | 1-1/4” NPT | ||
Warranty: | Limited one (1) year on materials and workmanship | ||
Shipment: | 4 weeks from acceptance of purchase order | ||
Training: | Free Operational training available at our facility in Cleveland, OH. On-site start up and training assistance can be quoted | ||
Utility Requirements | |||
Electrical: | SCCH20 | 120V, 240V | Other Voltages Available |
SCCH21 | 120V, 240V, 480V | ||
SCCH22 | 240V, 240V-3ph or 480V-3ph | ||
Compressed Air: | SCCH20-22 | Air Pressure Air Volume | 40-120 psi maximum 40-50 scfh @ 12-18 psi |
City Water: | All | Should be made available with the use of a shutoff valve and hose arrangement in the test area near the unit. Up to 100 gallons needed at initial installation / start up | |
Deionized Water (ASTM D1193 Type IV): | All | Used for filling reservoirs and for electrolyte solution makeup (up to 6 gallons per day) | |
Exhaust: | SCCH20-22 | 1” npt | |
Drain: | All | 1/2” npt | Corrosion resistant piping (ie) PVC |
Model # | Capacity | Inside Dimensions Exposure Zone Depth | Outside Dimensions (cover closed) |
SCCH 20 | 9.3 ft3 (264 liters) | 30" x 18" x 30" (76 x 45 x76 cm) | 50" x 28" x 48" (62" open) 127 x 72 x122 cm (158 open) |
SCCH 21 | 18 ft3 (510 liters) | 36" x 24" x 36" (92 x 61 x 92 cm) | 56" x 34" x 56" (74" open) 142 x 86 x142 cm (188 open) |
SCCH 22 | 30 ft3 (850 liters) | 48" x 30" x 36" (122 x 76 x 92 cm) | 65" x 36" x 56" (78" open) 165 x 92 x 145 cm (198 open) |