Coil Coater Wet Film Thickness Gauges

Article No. 14030

Coating Thickness Gauge CC 2-6 Mil

  • Coil Coater Thickness Gauge
  • 2-6 mils range

Select your model

Certificate:

$651.00 excl. taxes & shipping cost

Features

  • Direct Reading
  • High Precision
  • Circular Type
  • Standard Gauge For Testing Coil Coatings

These Coil coater gauges have an eccentric disk between two outer disks. This design is slightly different from the Gardco Model "C" wet film gauges that have the eccentric disk in front of the other two disks. (Reference leaflet "Model C Wet Film Thickness Gauge with Optional Handle".) The gauge is in the form of a wheel, the perimeter having three equally spaced disks. The center disk is smaller and eccentric to the outer ones. When the gauge is rolled over a wet film, the center disk will pick up material immediately when contact is made. The reading is taken from the point at which this contact first appears. For this purpose, a calibrated scale is engraved on one side of the gauge so it is possible to read film thickness with an accuracy of 0.0002".

Technical Attributes

  • Data
    Part Number:1403014034
    Gauge Range:2-6 mils4-8 mils
    Smallest Graduation:0.2 mils0.4 mils
    Recommended Use Range:2.4 - 5.6 mils-
    Tolerance Limits:0.2 mils0.4 mils
    Size:2" dia x 0.640" wide

More Information

Conversion Table - 1 Mil = 0.001 Inches = 0.0254001 Millimeters = 25,4001 Microns
MilsMillimetersMicronsMilsMillimetersMicronsMilsMillimetersMicrons
0.10.00252.55.750.146146.022.50.572572.0
0.20.00515.16.000.152152.023.00.584584.0
0.30.00767.66.250.159159.023.50.597597.0
0.40.010210.26.500.165165.024.00.610610.0
0.50.012712.76.750.171171.024.50.622622.0
0.60.015215.27.000.178178.025.00.635635.0
0.70.017817.87.250.184184.025.50.648648.0
0.80.020320.37.500.191191.026.00.660660.0
0.90.022922.97.750.197197.026.50.673673.0
1.00.025425.48.000.203203.027.00.686686.0
1.10.027927.98.250.210210.027.50.699699.0
1.20.030530.58.500.216216.028.00.711711.0
1.30.033033.08.750.222222.028.50.724724.0
1.40.035635.69.000.229229.029.00.737737.0
1.50.038138.19.250.235235.029.50.749749.0
1.60.040640.69.500.241241.030.00.762762.0
1.70.043243.29.750.248248.031.00.787787.0
1.80.045745.710.000.254254.032.00.813813.0
1.90.048348.310.250.260260.033.00.838838.0
2.00.050850.810.500.267267.034.00.864864.0
2.10.053353.310.750.273273.035.00.889889.0
2.20.055955.911.000.279279.036.00.914914.0
2.30.058458.411.250.286286.037.00.940940.0
2.40.061061.011.500.292292.038.00.965965.0
2.50.063563.511.750.298298.039.00.991991.0
2.60.066066.012.00.305305.040.01.0161016.0
2.70.068668.612.50.318318.041.01.0411041.0
2.80.071171.113.00.330330.042.01.0671067.0
2.90.073773.713.50.343343.043.01.0921092.0
3.00.076276.214.00.356356.044.01.1181118.0
3.10.078778.714.50.368368.045.01.1431143.0
3.20.081381.315.00.381381.046.01.1681168.0
3.30.083883.815.50.394394.047.01.1941194.0
3.40.086486.416.00.406406.048.01.2191219.0
3.50.088988.916.50.419419.049.01.2451245.0
3.60.091491.417.00.432432.050.01.2701270.0
3.70.094094.017.50.445445.051.01.2951295.0
3.80.096596.518.00.457457.052.01.3211321.0
3.90.099199.118.50.470470.053.01.3461346.0
4.000.102102.019.00.483483.054.01.3721372.0
4.250.108108.019.50.495495.055.01.3971397.0
4.500.114114.020.00.508508.056.01.4221422.0
4.750.121121.020.50.521521.057.01.4481448.0
5.000.127127.021.00.533533.058.01.4731473.0
5.250.133133.021.50.546546.059.01.4991499.0
5.500.140140.022.00.559559.060.01.5241524.0

Standards

ASTM

D1005 D1212 D823 D1186 D1400 E376-69

FTMS

6141c 6183

ASTM D3794 

Procedure

  1. The gauge is placed on a freshly coated surface at the high range position (6 mils/or 8 mils) and rolled in one direction for one half a revolution. It is then lifted and placed on another area with its high range in contact with the surface. It is then rolled in the opposite direction for one-half a revolution.
  2. Examination of the center disk will show positions at which pick-up has taken place and the scale will show wet film thickness at each point. For clear coatings, dust the center wheel with talc. Blow off talc. Talc will only adhere to wetted portion of disk. Read scale at end of wet point.
  3. Gardco Coil Coater IC type Thickness gauge is rolled over the film and the wet film thickness is read directly from the gauge. Accuracy of 0.0002".
Join our Email List. subscribe