S90 ZAHN Viscosity Cup |
 |
An All Stainless Steel Calibrated Viscosity Dip Cup |
 |
|
- The S90 Zahn Dip Viscosity Cup is an improved version of the time honored Zahn Signature Series Viscosity Cup. GARDCO is the only producer authorized to use the Zahn name and has added the S90 designation to identify the improved viscosity cups manufactured on new state-of-the-art equipment to insure optimum quality and uniformity.
- Calibration of the S90 Zahn Dip Cup matches the earlier Zahn Signature Cup.
- Conversion formulas and tables relating flow cup efflux time in seconds to viscosity in centistokes are identical for both series of viscosity cups.
- S90 Zahn Viscosity Cups qualify for certification under ANSI/NCSL Z540 or ISO/IEC 17025, ISO 9001, as applicable.
- S90 Zahn cups are calibrated with standard "G" series oils traceable to the National Institute of Standards & Technology (NIST).
- "G" series Canon calibration oils (standards) are produced in accordance with ISO 9002.
- NOTE: Efflux time from these viscosity cups does not meet ASTM specifications. Tables are available for converting S90 Zahn cup efflux time to EZ™ Zahn cup efflux time which complies with ASTM D4212.
|
|

|
Features
- Viscosity Cup flow characteristics are defined by a mathematical formula and standard “G” series Canon Calibration oils.
- Furnished with each S90 Zahn dip cup is a conversion table relating cup efflux time to the nearest tenth of a
second to viscosity in centistokes.
- S90 Zahn Visosity cups, with the above advantages, cannot be confused with other, lesser defined cups as they are
produced, calibrated and sold only by Paul N. Gardner Company and authorized dealers.
- Ransom & Randolph recommends the S90 Zahn Viscosity Cups as the most reliable viscosity cups to measure and
control the consistency of ceramic shell slurries.
- S90 Zahn Dip cups do not meet ASTM Specification D4212. Not all S90 Zahn Cups deviate from the standard by the same amount - the range being from near compliance to a variance exceeding a factor of two. Manufacturing procedures include calibration with oils traceable to the National Institute of Standards and Technology (NIST). Certification with compliance to ANSI/NCSL Z540 or ISO/IEC 17025, ISO 9001, as applicable, is available at our Gardco Service Department. Tables are available which convert between S90 Zahn Signature and EZ™ cups of the same number, to the nearest tenth of a second, to assist those who need to work with both established standards.
|
Technical Data
Instructions for Use
- Select the cup to be used from the Range Specification table.
- Insure that the cup is clean, especially around the orifice.
- Adjust temperature of the material to be tested, if necessary.
- Holding the cup by the ring, immerse it into the test material.
- Measure and record temperature of material encompassed by cup.
- Hold cup vertically by inserting index finger into handle ring. In a quick, steady motion, lift the cup out of the sample material, starting the timer when the top edge of the cup breaks the surface. During the flow time, hold the cup no more than 6” above the level of the sample material.
- Stop the timer when the first definite break in the stream at the base of the cup is observed.
- Record cup name, number and efflux time in seconds with temperature.
- Promptly clean the cup taking care not to abrade orifice. Use a length of nylon fishing line to clean the orifice.
|
Viscosity Cup Care
GARDCO produced and calibrated S90 Zahn viscosity cups are made of stainless steel except for the name plate. These cups will give years of satisfactory service requiring only thorough cleaning following each use. Even so, it is good practice to periodically confirm cup calibration. This is easily done with use of appropriate “G” oil listed in the Calibrating Oils table. Centistoke label value of the oil is traceable to the National Institute of Standards and Technology.
Guide for removing the G-series calibrating oil from Gardco viscosity cups.
Any remaining material in the cup must be removed by flushing with a suitable solvent. Light naphtha,
heptane, octane, highly aromatic solvents, and or any other petroleum-derived hydrocarbon solvent
can be used. Varsol® is a commercial solvent that works very well for this purpose. Varsol is a registered trademark of the Exxon Company
Completely dry the viscosity cup with a lint free cloth. Use a highly volatile solvent for a second cleaning
as since any remaining hydrocarbon solvents from the first process will evaporate quickly after the
sample has been flushed from the cup. Hypersolve, MEK and Alcohol can be used in aluminum cups
and Hypersolve and Alcohol for the stainless steel cups. Acetone is commonly used as the second
solvent because of its high volatility and its ability to dissolve traces of petroleum solvents and water.
In the third process a low velocity stream of clean air will be sufficient to evaporate remaining traces of
any volatile solvent. Be aware, avoid rapid evaporation of these solvents as this can cool the surface
to such an extent that humid air may be brought below the dew point, causing a film of water to form
on the cup. |
Accessories
EZ Cup Demo Video
|
Price
|
 |
 |
 |
Prices subject to change Prices listed in US dollars for domestic shipments within US For tax exempt orders please call us at 954-946-9454 |
|
Item Number |
Item |
Prices |
VI-2101 |
No. 1 S90 Zahn Viscosity Cup |
|
VI-2102 |
No. 2 S90 Zahn Viscosity Cup |
|
VI-2103 |
No. 3 S90 Zahn Viscosity Cup |
|
VI-2104 |
No. 4 S90 Zahn Viscosity Cup |
|
VI-2105 |
No. 5 S90 Zahn Viscosity Cup |
|
107413795 |
Calibration Certificate for Viscosity Cups - add this to your cart with any above cup. Certification to ISO 17025 will take 3-5 days (shipping time not included).This item must be added for each cup you need certified. |
|
Learn more about our FREE viscosity calculater. CLICK HERE. |
Viscosity Oils |
VI-3805 |
G-20 Certified Viscosity Standard - Pint |
104.00 |
VI-3815 |
G-60 Certified Viscosity Standard - Pint |
104.00 |
VI-3820 |
G-100 Certified Viscosity Standard - Pint |
104.00 |
VI-3825 |
G-350 Certified Viscosity Standard -Pint |
104.00 |
Accessories |
VI-201901 |
Aluminum Carousel Stand w/5 Hooks |
|
TM-AX705 |
Ultimate Stopwatch, 1/100 |
37.00 |
TM-AX705/C |
Ultimate Stopwatch, 1/100 - Certified traceable to N.I.S.T |
63.00 |
TH-0482 |
Thermometer, Glass, blue spirit filled, 4-1/2", 20° to 30°C |
64.00 |
TH-16100860 |
GT-100R Thermometer, Stainless, 8" Stem, 25° to 125°F |
45.00 |
TH-16100875 |
GT-100R Thermometer, Stainless, 8" Stem, 0° to 50°C |
45.00 |
SS-80600 |
Griffin Beaker SS, 600 ml |
62.00 |
VI-VCC |
Viscosity Cup Equivalent Wall Chart (download here) |
FREE |
Equivalent Charts cover Gardco Calibrated Viscosity Cups and are based on conversion formulas of a type & with parameters as referenced in The Encyclopedia of Polymer Science & Engineering (Vol. 4, Second Edition, John Wiley & Sons, Inc.). Standard oils traceable to the National Institute of Standards & Technology were used in experimental development of these formulas. |
Viscosity Cups are non-returnable items. Subject to final sale. |
S90TM is a Registered Trade Mark of the Paul N. Gardner Company, Inc |
 |
|
|
|