Home  >>  Products  >>  Optical Instruments  >>  In-Line Refractometer and Brix-Monitor
In-Line Refractometers

PRM-100α

top

 

The PRM-100α in-line refractometer measures the refraction of light generated between the prism surface and a liquid sample.

In-Line Refractometer
  • Wider than ever 0.0 to 100.00% Brix range
  • Improved measurement accuracy: Brix ±0.05%, nD ±0.00010
  • Two options for setting the minimum indication decimal place
  • Simple two-piece construction: detection section and operation display section
  • Easy-to-read color display panel

 

Technical Data for PRM-100α

top
Technical Data for PRM-100α
Measurement Item: One of Refractive Index (nD), Brix (temperature compensation according to sucrose solution), concentration (%) (temperature compensation according to samples), and temperature
Measurement Range: Refractive index (nD) 1.32000 to 1.55700
Brix 0.0 to 100.00%
Minimum Indication: Refractive index (nD) 0.0001 or 0.00001
Brix or concentration 0.1% or 0.01% by selection
Measurement Accuracy: Refractive index(nD) ±0.00010
Brix ±0.05%
Measurement Temperature: 5 to 100°C
Output Method: RS-232C, DC4 to 20mA
Alarm Output: Open-collector output for high and low limit settings (alarm output)
Power Supply: AC 100V to 240V, 50/60Hz
Waterproof Protection Class: IP65
Dimensions & Weight: Detection section: 12.8 x 26.6 x 12.8cm, 3.3kg
Calculation Display section: 19.2 x 10.0 x 24.0cm, 3.3kg

 

PRM-2000α

top
Introducing An Ideal In-line Unit for Low Concentration Samples

Featuring a Brix range of 0 to 20%, with a high accuracy of ±0.050%, our newest in-line unit, the PRM-2000α is ideal for precision measurement of low concentration samples, as well as fruit juices and other beverages. Moreover, the PRM-2000α has an even higher accuracy of ±0.007% for samples with a low Brix range of 0.000 to 2.000%. The detection section is able to withstand temperatures between -30 to 165°C (during SIP / CIP).
In-Line Refractometer

 

Technical Data for PRM-2000α

top
Technical Data for PRM-2000α
Measurement Item: Refractive index, Brix (Automatic temperature correction suitable for sucrose, high-fructose corn syrup and sugar-free (2% or less)), concentration (%) (temperature compensation according to samples), Temperature
Measurement Range: Refractive Index nD 1.32069 to 1.36500
Brix 0.000 to 20.000%
Resolution: nD 0.00001
Brix 0.001%
Measurement Accuracy: nD ±0.00001 (1.32069 to 1.33681)
nD ±0.00010 (from 1.33682 up)
Brix ±0.007% (0.000 to 2.000%)
Brix ±0.050% (from 2.001% up)
* When measuring standard solutions under stable temperature condition
Measurement Temperature: 0 to 100°C
Temperature Compensation Range: 5 to 90°C
Wetted Parts Temperature Resistance: -30 to 165°C during CIP/SIP (max 30 min)
Light Source: LED (D-line approximation)
Materials in Contact with the Solution: Prism : Sapphire
Prism stage : SUS316L
Prism Pressure Resistance: 0.98MPa(10Kgf/cm2)
Display Item: Refractive index, Brix (CH1 to 3), Concentration, Temperature (°C)
High and Low Limit Setting: Open-collector output for high- and low-limit settings (Alarm output)
Output: RS-232C or DC4 to 20mA
Output Item: Refractive index or Brix (CH1 to 3) or Concentration, Temperature (°C)
Display System: Seven-segment LED
Alarm Output: Open-collector output for high- and low-limit settings (Alarm output)
Cable: Between the detection section and calculation display section (15m) (maximum up to 200m)
Power Supply: AC100V 50/60Hz
International Protection Class: Detection section : IP67
Display section : IP67
Dimensions & Weight: Detection section : 10.8 x 41.35 x 10.8cm, 4.1kg
Calculation Display section : 19.2 x 10 x 24cm, 3.3kg
Power Consumption: 30VA
Pressure Resistance: 1.0MPa (Detection section)

 

PRM-TANKα

top

The PRM-TANKα Process Refractometer features a new design of the detection unit, which is to be mounted on the wall of a vessel.

It is ideal for a variety of vessel types, such as distillers, condensers, blenders, fermenters, extractors, and filtration tanks. The flat sample stage prevents sample buildups, keeping the prism clean over an extended period of time.

In-Line Refractometer

 

Technical Data for PRM-TANKα

top
Technical Data for PRM-TANKα
Measurement Item: Refractive Index (nD) Brix (temperature compensation for sucrose) concentration (temperature compensation specific for the solute) and temperature
Measurement Range: Refractive index (nD) : 1.31700 to 1.51000
Brix : 0.00 to 85.00%
Resolution: Refractive index (nD) : 0.0001 or 0.00001
Brix : 0.1 or 0.01% (by selection)
Measurement Accuracy: Refractive index (nD) : ±0.0001
Brix : ±0.1%
Measurement Temperature: 5 to 40°C
Temperature Compensation Range: 5.0 to 100.0°C
Light Source: LED (D-line approximation)
Materials in Contact with the Solution: Prism - synthetic sapphire
Prism O-ring - FEP, PTFE
Flange O-ring - PTFE
Prism stage - SUS316L
Display: Refractive Index, Brix, Concentration, Temperature (°C)
High and Low Limit Setting: High and low control limits can be set with keys
Output: RS-232C, DC4 to 20mA
Output Item: Refractive index (nD), Brix, Concentration(%), Temperature (°C)
Display System: Seven-segment LED
Alarm Output: Open-collector output for high and low limit settings (alarm output)
Cable: Cable between the detection and display units : 15m standard (extension available up to 200m)
Power Supply: AC 100 to 240V, 50 / 60Hz
International Protection Class: Detection section : IP67
Calculation Display section : IP67
Dimensions & Weight: Detection section : 25 x 29.73 x 25cm, 12.3kg
Calculation Display section : 19.2 x 10 x 24cm, 3.3kg
Power Consumption: 30VA
Pressure Resistance: 1.0MPa (Detection section)

 

 

 

In-Line Brix-Monitor

CM-800α measures Brix or concentration of liquid flowing through a pipe at temperatures up to 100°C

This new addition to the CM series (CM-800α) is compatible with the PRM-100a fittings. The accuracy is ±0.1% across the entire range of 0-80% Brix.

CM-800a

 

Technical Data for Brix-Montior

top
Technical Data
Measurement Scale: Brix(%) (automatic temperature compensation according to the sample liquid)
Measurement Range: Brix 0.0 to 80.0%
Minimum Indication: Brix 0.1%
Measurement Accuracy: Brix ±0.1%
Measurement Temperature: 5 to 100°C (automatic temperature compensation range)
Ambient Temperature: 5 to 40°C
Output: (1) Recorder output: DC4 to 20mA (2) RS-232C output
Materials in contact with the solution: Prism: Sapphire; Prism stage: SUS316
Waterproof protection Class: IP64
Power Supply: DC24V
Accessory: Power input cable (1m)
Dimensions and Weight: 16 x 17 x 11cm, 2.4kg
Details of your application will help in the selection of required installation accessories.

 

 

 

In-Line Ethylene Glycol Monitor

The CM-800α-EG is specifically designed for in-line concentration measurements of ethylene glycol solutions used as coolants, brine, anti-freeze and de-icing fluids. It also has a secondary scale for the freezing point. In-Line Monitor

 

Technical Data For Ethylene Glycol Monitor

top
Technical Data
Measurement Scale: E.G. (ATC)
Measurement Range: E.G. 0.0-90.0%, Freezing point 0 to -50°C, Temperature 0-99°C
Resolution: E.G. 0.1%, Freezing point 1°C, Temperature 1°C
Measurement Accuracy: E.G. ±0.4%, Freezing point ±1°C, Temperature ±1°C
Measurement Temperature: 5 to 100°C (ATC)
Ambient Temperature: 5 to 40°C
Output Method: RS-232C, DC 4 to 20mA
Materials in contact with the Solution: Prism: Sapphire
Prism stage: SUS316
International Protection Class: IP64 water resistant
Power Supply: DC24V
Accessory: Power input cable (1m)
Dimensions and Weight: 16 x 17 x 11cm, 1.8kg

 

 

 

CM-BASEα

CM-BASEa

In-Line Brix-Monitor
Display Side
CM-800a
Optional Hose connector 12mmϕ RE-67501

Optional Compression Fitting 10mmϕ RE-67503

 

Features

top
  • Optimized for automation of real-time concentration monitoring.
  • Simple specification
  • Easy to use
  • Compact size
  • Inline model
  • Dimensions (main unit only)
  • Unit of length: mm
  • Cable Length: Approx 2m
Dimensions
Dimensions with Cable

 

Technical Data for CM-BASEα

top
Technical Data CM-BASEα (A) CM-BASEα (D)
Measurment Range Brix: 0.0 to 33.0%
Resolution Brix: 0.1%
Measurement Accuracy: Brix ±0.5% Temperature ±2.0°C
Measurement Temp.: 10 to 50°C (ATC = Automatic Temperature Compensation)
Ambient Temp.: 10 to 40°C
Output Method: DC4 to 20 mA RS-232C
International Protection Class: IP64 Water resistant
Dimensions & Weight : 90 x 90 x 59mm, 860g (Main unit only)

 

Models

top
CM-BASEα (A)
The CM-BASEα (A) transmits data via 4-20mA signals.

The provided cable connects to the base of the CM-BASEα (A), and it provides power (24VDC) to the instrument and transmits Brix data via DC 4-20mA. Brix values ranging from -2.0 to 33.5% are communicated as DC ranging from 4 to 20mA respectively.

The cable can be ordered to a custom length of up to 100m.


Cord Color Signal Cord Color Signal
Red 24VDC Black GND (24VDC)
Red/White 4DC to 20mA Black/White GND (4DC to 20mA)

 

CM-BASEα (D)
The CM-BASEα (D) transmits data to a computer via RS-232C.

The provided cable connects to the base of the CM-BASEα (D), and it provides power (24VDC) to the instrument and transmits Brix and temperature data via RS-232C. The cable can be ordered to a custom length of up to 15m.

Communications Parameters - Baud rate: 2400bps, Data length: 7bit, Parity: Even, Stop bit: 1bit

Transmit Data - aa.a,bb.b (Brix, Temperature)
Brix 19.5% = 19.5 (example)
Temperature 20.3°C = 20.3 (example)


Cord Color Signal Cord Color Signal
Red 24VDC Black GND (24VDC)
Red/White RS-232C Black/White GND (RS-232C)


Prices

top
Prices subject to change    Prices listed in US dollars for domestic shipments within US, Canada, & Mexico only    Export orders require quotations - click here for a quote     For more info call us 1-800-762-2478 or 954-946-9454.
Item Number Item Prices
RE-3574 PRM-100α In-line Refractometer
$17,800.00
RE-3641 PRM-2000α In-line Refractometer 18,400.00
RE-3575 PRM-TANKα In-line Refractometer 17,800.00
RE-3564 CM-800α In-line Brix-Monitor 5,200.00
RE-3531 CM-800α-EG In-line Ethylene Glycol Monitor 5,700.00
RE-3603 CM-BASEα (A) Refractometer 3,200.00
RE-3604 CM-BASEα (D) Refractometer 3,200.00
RE-67501 Hose Connector 12mmØ P.O.R.
RE-67503 Compression Fitting 10mmØ P.O.R.
Accessories
RE-3528 AC Adapter, 110V for Brix Monitor P.O.R.
RE-3529 AC Adaptor, 220V for Brix Monitor P.O.R.
Fitting Options for PRM-100α, CM-800α and CM-800α-EG
RE-6645 Sample inlet unit Hose connector 12mm φ Fitting 6645 P.O.R.
RE-6651 Sample inlet unit Compression fitting 10mm φ Fitting 6651 P.O.R.
RE-6658 Sample inlet unit IDF/ISO Clampunion (ferrule) 1S Fitting 6658 P.O.R.
RE-6676 Sample inlet unit IDF/ISO Clampunion (ferrule) 1.5S P.O.R.
RE-6659 Sample inlet unit IDF/ISO Clampunion (ferrule) 2S Fitting 6659 P.O.R.
Optional Accessory for PRM-100α, PRM-2000α and CM-800α
RE-9112 US-α Ultrasonic Cleaner, prevents debris from adhering to the prism surface. Can be affixed in the piping system. Fitting 6645 P.O.R.
Details of your application will help in the selection of required installation accessories.



top

Call HAVE QUESTIONS?
    1-800-762-2478
Email PREFER TO EMAIL?
    gardner@gardco.com
  FIND PRODUCTS LEARN MORE ORDERING INFO ABOUT US
  By Category Email Registry How to Order Contact Info
  By Industry Trade Shows Request Quote History
  New Products Test Lab Info Order Form FAQ's
  Monthly Product Articles/Links Sales & Clearance Policies




  © 2019 Paul N. Gardner Company, Inc. | Contact | Policies Facebook  Twitter  YouTube  Blogger