Features

  • The Mitutoyo Surftest® Surface Roughness Testers are both portable and highly versatile
  • They deliver accurate measurements at high speeds
  • Available in two models, handheld SJ-220 and the SJ-310 which is equipped with extensive measurment and analysis features
  • Compact, portable, and both have easy-to-use touch screens
  • Fully automatic, high-resolution measurement and high-speed positioning
  • Simultaneous measurement of surface roughness and contour
  • Multiple languages can be selected and are switchable
  • Highly functional detectors and drive units with quick-charge and a long-life battery
  • Calculation results are displayed in large characters
  • Up to 10 measurement conditions can be stored in the internal memory. Conditions can be quickly read according to the workpiece and can be printed out by the built-in thermal printer (SJ-310 Only)
  • Many interface options: A USB interface is equipped as standard, and an RS-232C output, Digimatic output, printer output, and foot switch input.
  • The SJ-220 Models now have a 2.8-inch touchscreen and wireless connectivity capabilites. They now conform to ISO 21920
  • The SJ-310 supports a micro-SD card (optional) for storage of up to 10,000 measurement values, 500 measuring conditions, 1000 measuring data, 500 image (BMP) data, 500 statistic data or auto save up to the last 10 sets of measurement data

Technical Attributes

  • Data
    Type of DetectorSJ-220 Standard Drive UnitSJ-310 Standard Drive Unit
    Part No.:155071550813130
    Traverse Length:-.7" (17.5 mm)
    Measuring: (Detector)Range:360 µm (-200 µm to +160 µm)  / 14400 µin (-7900 µin to +6300 µin)
    Range/Resolution:14400 µin / .8 µin (360 µm / 0.02 µm)
    4000 µin / .2 µin (100 µm / 0.006 µm)
    1000 µn / .08 µin (25 µm / 0.002 µm)
    Tracing Speed:Measuring 0.01, 0.02, 0.03 in/s (0.25mm/s, 0.5mm/s, 0.75mm/s) Returning 1 mm/s
    Measure Force/Stylus Tip:0.75 mN type: 0.75mN/2μuR 60°, 4mN type: 4mN / 5μmR 90°
    Skid Force:Less than 400mN
    Assessed Profiles:Primary profile / Roughness profile / DF profile / Roughness profile-Motif
    Evaluation Parameters:Ra, Rc, Ry, Rz, Rq, Rt, Rmax*1, Rp, Rv, R3z, Rsk, Rku, RPc, Rsm, Rz1max*2, S, HSC, RzJIS*3, Rppi, RΔa, RΔq, Rir, Rmr, Rmr(c), Roc, Rk, Rpk, Rvk, Mr1, Mr2, A1, A2, Vo, Rpm, tp, Htp*4, R, Rx, AR, Possible Customize
    Analysis Graphs:Bearing area curve / Amplitude distribution curve
    Filters:Gaussian, 2CR75, PC75
    Cut Off Length:λc0.003, 0.01.0.03, 0.1” (0.08, 0.25, 0.8, 2.5mm)
    λs*5100, 300μin (2.5, 8μm)
    Sampling Length:0.003, 0.01, 0.03, 1” (0.08, 0.25, 0.8, 2.5mm)
    Number of Sampling Lengths: (xn)x1, x2, x3, x4, x5, x6, x7, x8, x9, x10,
    Arbitrary .0118 ~ .22"(.0001" Interval) [(0.3 ~ 5.6mm: 0.01mm Interval)]
    LCD Dimensions:2.8" TFT colo LCD touch panel with backlight (320x240 dot)4.64" x 3.47" (117.8 x 88.2 mm)
    Display Languages:Japanese, English, German, French, Italian, Spanish, Portuguese, Korean Traditional Chinese, Simplified Chinese, Czech, Polish, Hungarian, Turkish, Swedish, Dutch, Russian, Slovenian, Romanian, Bulgarian, Finnish, Thai, Vietnamese, Indonesian and MalayJapanese, English, German, French, Italian, Spanish, Portuguese, Korean Traditional Chinese, Simplified Chinese, Czech, Polish, Hungarian, Turkish, Swedish, Dutch
    Measurement Result Display:Vertical display: 1 parameter / 3 parameter / trace to measurements
    Horizontal display: 1 parameter / 4 parameter / trace to measurements
    (Horizontal display is invertable)
    1-parameter display: one parameter measurement result 4-parameter display: four parameter measurement results Profile display: one parameter measurement result and the measured profile Trace display: The ten latest measurement results using the same parameter
    Printing function*6: (Dedicated printer is required separately)Measurement conditions / Calculation results / Calculation results for each sampling length / Assessed profile / Bearing area curve / Amplitude distribution curve / Environment setting information
    External I/O:USB I/F, Digimatic Output, Printer Output, RS-232C I/F, Foot SW 1/F
    Functions:CustomizationDesired parameters can be selected for calculation and display
    GO/NG judgment*7By max value / 16% / Standard deviation
    Storage of Measurement ConditionSave the condition at power OFF
    StorageInternal memory: Measurement condition (10 sets), Measured profile (1 set), Memory card (Option): 500 measurement conditions, 10000 measured profiles, 500 display images, Text file (Measurement conditions / Measured profile / Assessed profile /
    Bearing area curve / Amplitude distribution curve)
    Calibration:Auto-calibration with the entry of numerical value / Average calibration with multiple measurement (Max 5 time) is availableAuto-calibration with the entry of numerical value / Average calibration with multiple measurement (Max 12 time) is available
    Power-Saving Function:Auto-sleep off function (10-600sec) *8Auto-sleep function (30-600 sec)
    Power Supply:Two-way power supply: baqttery (rechargeable Ni-MH battery) and AC adapter
    *Charging time: about 4 hours (may vary due to ambient temperature)
    *Endurace: about 1000 measurements (differs slightly due to use conditions / environment)
    Two-way power supply: battery (rechargeable Ni-MH battery) and AC adapter Note 1: Charging time: about 4 hours (may vary due to ambient temperature) Note 2: Endurance: about 1500 measurements (differs slightly due to use conditions /environment)
    Size:
    W x D x H
    Display Unit:164.7 x 67.1 x 51.9 mm10.8" x 4.3" x 7.8" (275 x 109 x 198 mm)
    Drive Unit:115 x 23 x 26 mm4.5"x 0.9" x 8.9" (115 x 23 x 26.7 mm)
    Mass:About 1.1 lbs. (500 g) (Display unit + Drive unit + Standard detector)About 3.9 lbs. (1.8 kg) (Display unit + Drive unit + Standard detector
    Standard Detector
    Measuring Force:0.75 mN4 mN
    Stylus Tip:Radius 2 µmRadius 5 µm
    Tip Angle:60°90°
    *1 Calculation is available only when selecting the VDA, ANSI, or JIS '82 standard.
    *2 Calculation is available only when selecting the ISO '97 standard.
    *3 Calculation is available only when selecting the JIS '01 standard.
    *4 Calculation is available only when selecting the ANSI standard.
    *5 Not available when selecting the JIS '82 standard.
    *6 Order the SJ-210 printer (178-421, optional accessory) separately. See page 19 for details about the SJ-210 printer.
    *7 Standard deviation only can be selected in ANSI. 16 % rule cannot be selected in VDA.
    *8 Auto-sleep function is invalid when AC adaptor is used.

Standards

JIS B 0601:1982, JIS B 0601:1994, JIS B 0601:2013, JIS B 0601:2002, JIS B 0601:2000
ISO 4287:1997, ISO 13565:1996, ISO 12085:1996, ISO 21920:2021, ASME B46.1, VDA2006

Delivery Content

SJ-210 - Connecting cable, Roughness specimen Ra (3 µm), Carrying case, Calibration stage Protective sheets for display, AC Adapter, Operation manual, Quick reference manual, Warranty

SJ-310 - Connecting cable, Roughness reference specimen (Ra3 µm), AC adapter, Nosepiece for plane surface, Nosepiece for cylinder, Supporting leg, Calibration stage Stylus pen, Protection sheet, Printer paper (5 pieces), Carrying case Philips screwdriver, Strap for stylus pen, Operation manual, Quick reference manual, Warranty

Join our Email List. subscribe