Introduction
|
All processors of liquid or semi-liquid materials are concerned with the ‘flow property’ of
their products. This ‘flow property’, a sort of internal friction resisting flow, is measured as
viscosity. Normally the amount of diluent in such products controls the viscosity of the
product. Therefore, measuring viscosity is necessary not only to insure required and uniform
product performance but also to control product cost.
The fundamental unit of viscosity is the Poise. It is the force required to move one surface
of a known area at a given velocity with respect to another surface when the two surfaces are
separated by a viscous material. The Centipoise is the Poise divided by 100. The
Stoke is the Poise divided by product density (or weight per gallon in pounds multiplied
by 0.1202) and is the unit of measure when gravity is the force causing product flow. When
the Stoke value is known, the equivalent Poise value may be found by multiplying the
Stoke value by product density (or weight per gallon in pounds multiplied by 0.1202). The
Centistoke is the Stoke divided by 100.
|
| Instrumentation commonly used for measuring viscosity can broadly be
divided into two types: |
- Rotational which measure in Poises
- Viscosity Cups which measure in Stokes
|
There are many other specialty types of viscosity measuring instruments but they are beyond the scope of this writing.
Most rotational instruments operate at more than one speed to permit a product to be
evaluated at various rates of shear. They are, therefore, applicable to a higher level of product
evaluation than viscosity cups. They are also applicable to the evaluation of materials
containing a high ratio of solid materials and products that are above the range of instruments
depending on gravity as a driving force. They are also expensive. Prices range depending on degree of sophistication, range,
temperature control and data display.
Measuring viscosity by the use of viscosity cups has become the preferred method for
production control due to their ease of use, their rugged nature, recent improvements in
accuracy and relatively low cost. |
Viscosity cups fall into two different types with those standardized and
calibrated by the Paul N. Gardner Company shown for each type as
follows:
Dip Viscosity Cups
EZ (Equivalent Zahn) Viscosity Cups - 5 Cup Ranges
Zahn Signature Cups - 5 Cup Ranges
Ford Dip Viscosity Cups - 6 Cup Ranges
Gardco/Fisher Dip Viscosity Cups - 4 Cup Ranges
Laboratory or “Ring Stand” Viscosity Cups
Ford Standard Viscosity Cups - 6 Cup Ranges
Gardco/ISO Viscosity Cups - 3 Cup Ranges |
Much confusion has resulted in the selection of, as well as the use of ,viscosity cups due to
the number of types available and inadequate standardization between the various manufacturers.
It is the purpose of the balance of this writing to present the most common questions
asked and the answers to these questions.
The questions are grouped into the following categories:
A. Cup Selection
B. Cup Accuracy
C. Cup Standardization and Certification
D. Cup Use
E. Temperature Control
|
A. Cup Selection
|
1.
|
Q. My company has just assigned me the responsibility of establishing a production control procedure for the measurement of viscosity. No such method exists at present. We are a small one plant company and our funds are quite limited. At present, we are not required to comply with such measurements from either
suppliers or customers but this situation will probably change. It is understood that measurement by viscosity cup is probably the easiest way, and the lowest cost, to start such a program but which viscosity cup should I buy?
A. The new EZ (Equivalent Zahn) Viscosity Cup is recommended. It is in the same price range as the Zahn Signature cup but it has the advantage of compliance with ASTM specifications which is most widely accepted by most users and you would be in a better position in the future, if, as you indicate, you might need to work with others.
|
| |
| 2. |
Q. What is the difference between the EZ Cup and the Zahn Signature Cup?
A. They are very similar in appearance and use. There are some design improvements in the EZ Cups not found in the Zahn Signature Cups but the main advantages are in compliance with ASTM specifications and in production procedures which permits closer tolerance to performance specification. EZ cups have a tolerance within 3%. Zahn Signature cup tolerance is within 5%.
|
| |
| 3. |
Q. Associates, in situations similar to mine, tell me that they use the Zahn Signature
Cups and they are well satisfied with their results. Should I decide on this cup,
even though it does not meet ASTM specifications, can I be assured that this
cup will continue to be available?
A. Yes. The Paul N. Gardner Company is committed to making this cup available as
long as there is a demand for it. In addition, conversion tables are available which
convert results between the Zahn Signature and the EZ cups. Also, production
procedures are being revised which will improve the uniformity of the Zahn
Signature cups. Cups produced under this new procedure will be known as Zahn
Signature Series 90 cups and they will comply with the flow characteristics of all
earlier Zahn Signature cups that we have sold, but remember, they do not conform
to that portion of the ASTM method which specifies drain time characteristics.
|
| |
| 4. |
Q. Why did you not recommend the Ford Dip Cup?
A. From your earlier question it was assumed that you were looking for the lowest
cost possible. If your budget would tolerate about 75% greater equipment
investment we would recommend this cup. It has the advantage of having a
readily removable orifice with a flow path length greater than its diameter. This
makes the cup more sensitive and accurate. It has the further advantage of
providing results which are just one half those obtained with the Standard Ford
Cup. This would be of considerable advantage if at a later time you established
a formal laboratory and wanted to use the very popular Standard Ford cup in your
laboratory work. Ford Cup tolerance is within 2%. Ford Cups are machined
from solid aluminum bar stock. Ford Dip Cups have six easily removable ,
interchangeable orifices from size no. 0 to no. 5. If you wish just buy one cup and
one or all of the orifices to fit it. This is a considerable cost saving.
|
| |
| 5. |
Q. What about the Gardco/Fisher Cup?
A. It is an excellent cup. It is also machined from solid aluminum bar stock and is
produced with a removable orifice of appreciable length. It contains a larger
volume than any of the other dip cups which gives it a significant accuracy
advantage. It is also the most expensive, costing more than the EZ cup by a factor
of about 2.5. There would be little reason for standardizing on this cup unless you
projected business with General Motors or one of its suppliers as it is not nearly
as widely used as the Zahn Signature, EZ or Ford Dip Cup. Gardco/Fisher Cups
have four easily removable, interchangeable orifices from size no. 1 to no. 4. If
you wish just buy one cup and one or all of the orifices to fit. This saves
considerable cost.
|
| |
| 6. |
Q. So far you have not mentioned the ISO (International Standards Organization)
Viscosity Cup. Would there be any advantage in my considering
this cup?
A. Not unless you contemplated future international business. It is a cup very
similar in appearance and in use as the Standard Ford Cup but with different
flow characteristics. This cup also has removable, interchangeable orifices.
|
| |
| 7. |
Q. Which of the cup numbers (ranges) should I buy?
A. It depends on the range of viscosity that you must consider. It may be helpful
for you to know that over a half of the EZ and Zahn Signature Cups sold are #2. The very lightest materials require #1 and the heaviest, #5.
|
| |
| 8. |
Q. How long does it take to make a viscosity measurement with the EZ
Viscosity Cup?
A. The recommended minimum is 1.5 times the number of seconds it takes water
to drain from the cup or 10 seconds, whichever is greater. Below the 1.5 limit
the measure is primarily turbulence at the orifice rather than viscosity. Below
10 seconds, errors in measuring drain time become too great. The maximum
drain seconds recommended is 60. Since the exterior of the cup becomes coated
with the test material, evaporation from the surface has a cooling effect on the
contents and a possible hardening on the surface either of which may result in
possible error. The minimum holds for all viscosity cups whether of the dip or
laboratory ring stand type. The maximum is for dip cups only as the laboratory
type, Standard Ford or ISO cups, do not become coated on the exterior.
|
| 9. |
Q. It sounds like the EZ or Zahn Cup would be the correct choice for my purposes
so I would like to ask additional questions relating just to these two types. Just
what is an EZ or Zahn Cup?
A. These cups are formed from Stainless Steel. They are bullet shaped (cylindrical
with a hemispherical bottom) with an orifice of specified size drilled in the exact
center of the spherical base. Welded to the cup is a stainless steel wire loop
extending twelve inches above the cup and terminating in a one inch ring. In use,
the cup is held by the ring and is dipped into the material to be measured. As the
cup is lifted from the material a timing device is started. The draining of the cup
is observed and the timing device is stopped on the first break in the efflux stream
about two inches below the base of the cup. Results are reported in efflux seconds.
|
| 10. |
Q. Is there more than one producer of the EZ Viscosity Cup?
A. No. The EZ Viscosity Cup is produced only by the Paul N. Gardner Company.
Production procedures followed by cup calibration results in drain time with a
specified viscous material, traceable to the National Institute of Standards and
Technology, being within 3% of target.
|
| 11. |
Q. Is there more than one producer of the Zahn Viscosity Cup?
A. Yes. The Zahn Cup is produced not only by different suppliers in the United
States but also in countries throughout the world such as England, France, Italy,
and West Germany. However, The Paul N. Gardner Company is the only licensed
producer by the inventor E. A. Zahn.
|
| |
| 12. |
Q. Will Zahn Cups of the same orifice size number from different producers
give the same readings on the same liquid?
A. No. Differences exceeding 50% have been observed.
|
| |
| 13. |
Q. How long have Zahn Viscosity Cups been in use?
A. Zahn Viscosity Cups have gained rapidly in popularity since the last
half of the 1940’s. |
| |
B. Cup Accuracy
Assuming that I proceed with the EZ Cup in my viscosity measuring program, I would
like to proceed with questions relating to the cup accuracy, cup standardization, use and
conditions under which viscosity measurements should be conducted.
|
14.
|
Q. Just what is meant by cup accuracy?
A. There are really two parts to this question and they are both important: Do cups
from the same producer and of the same number agree from cup to cup as well
as between cups purchased at a different time. The second part of the question
relates to the cups providing long term consistent results and preferably that are
related in some measurable way to fundamental units of viscosity.
|
| |
| 15. |
Q. It appears to me that the second part of the answer on cup accuracy is most important since if I make a length measurement with a 12 inch ruler I
assume that ruler is the same length as any other ruler that anyone else
might use. What about viscosity cups?
A. It is indeed a most important question and can be answered only for the cups
produced by the Paul N. Gardner Company. A study was funded early in the
1980’s to study this problem. One of the findings of this study was the necessity
to relate the cups to a standard superior to a dimensional drawing or a “standard” cup that a producer retained on the shelf. The answer was found in standard
viscous materials . These materials are specified in units of Centistoke Viscosity
with an accuracy to within 0.25% of label value and are traceable to the U.S.
National Institute of Standards and Technology. These materials are used in the
calibration of all viscosity cups produced by and are available from The Paul
N. Gardner Company.
|
| |
| 16. |
Q. What accuracy can I reasonably expect from any viscosity cup that I purchase
from The Paul N. Gardner Company?
A. For each of the cup numbers in each of the cup types produced by the Paul N.
Gardner Company, a series of standard calibration oils have been used, covering
the useful range of each cup, and from the data so gained a mathematical formula
has been accurately derived relating seconds of efflux time to centistoke viscosity.
This formula permits converting the centistoke value for a particular material
to drain time in seconds for a given cup. Since an appropriate calibration oil is
also used in cup calibration in the midpoint range of the cup as a final step in the
production process, and with tight control of all mechanical variables, we are able
to hold cups to within tolerance to this standard as follows:
Zahn Signature Cups 5%
EZ Viscosity Cups 3%
Ford Dip Viscosity Cups 2%
Gardco/Fisher Dip Viscosity Cups 2%
Ford Standard Cups 2%
Gardco/ISO Viscosity Cups 2%
This procedure not only insures that each cup within a given production lot falls
within these tolerance limits but also, since the standard calibration oils are
periodically renewed, that there is no long term drift away from the established
standard.
|
| |
| 17. |
Q. What should I look for in cups produced by others that might detract from
cup accuracy or agreement between cups?
A. This answer is limited to Zahn type cups only. |
| |
- Height to diameter of the cup as well as cup volume. Variance as much
as 12% has been observed in cup volume.
- The cup is not welded to the support wire loop to hold the cup axis in
symmetry with the support loop. This will cause the efflux stream to move
away from the center of the orifice resulting in large error.
- Orifice diameter. Most producers have accurately copied the published
diameter of the orifice. This is probably the greatest problem. Orifice
diameter is the one physical dimension that can be adjusted to compensate
for other cup variables. The orifice diameter of all cups produced by
the Paul N. Gardner Company is adjusted to provide conformance with
specified performance characteristics.
- The orifice is not in the exact center of the bottom of the cup. When
this occurs, the efflux stream will “bend” to the lower portion of the
orifice and large errors will result.
- The orifice is not round or uneven tooling marks are evident at either
end of the orifice. Either condition detracts from cup accuracy.
- Variation in cup sidewall thickness. A variation as much as 50% has
been observed. Since the orifice length is a function of sidewall
thickness and orifice length is a direct factor in flow time, a variation in
sidewall thickness is a serious condition.
|
| 18. |
Q. How does the orifice length influence drain time?
A. The longer the orifice length the greater the drain time. Drain time is very
roughly directly proportional to orifice length.
|
| |
| 19. |
Q. How does the orifice diameter influence drain time?
A. The greater the diameter of the orifice the shorter the drain time. The
diameter of the orifice is very critical. Drain time is very roughly inversely
proportional to the fourth power of the radius of the orifice.
|
| |
| 20. |
Q. If I purchase the EZ Cup, can I convert readings from this cup to other
cups produced by the Paul N. Gardner Company ?
A. Yes. Since all such Gardco cups are calibrated through a mathematical formula
to the common fundamental unit of viscosity measurement, the centistoke, any
drain time in seconds from any particular cup can be converted not only to
centistokes but also to any other Gardco cup where the conversion is within cup
range. A wall size chart, 24" x 36", is available showing this conversion for
each of the 29 cups making up the six types produced by the Paul N. Gardner
Company. This conversion is in 5% steps throughout the range from 7.5 to
1387 centistokes. The conversion is very accurate as long as the material in
question does not deviate greatly from a true liquid. The chart also contains
other important information such as cup range, cup formula constants, standard
oil used for calibration, cup sensitivity and standard cup use. |
| |
C. Cup Standardization and Certification
|
| 22. |
Q. Does the Zahn Signature cup meet the requirements of ASTM
Method D-4212?
A. No. The Zahn Signature Cups as originally licensed to the Paul N. Gardner Company fails only in meeting that portion of the method relating to drain time.
However, in order to accommodate the thousands of Zahn Signature Cup
owners who have established their records on the basis of these cups, they have
now been standardized with mathematical formulas relating drain time to
centistokes which permits converting their results to cups that do comply to
ASTM Method D-4212. In addition, conversion tables are also available which
convert results between the Zahn Signature and the EZ cups.
|
| |
| 23. |
Q. Do the EZ cups meet the requirements of ASTM Method D-4212?
A. Yes. This cup was designed specifically to meet the requirements of ASTM Method D-4212 in all respects. This step was taken to permit retention of the
standard established for the Zahn Signature Series and also provide a similar
series of cups of highest quality with improved design, standardized with
compliance to D-4212. EZ cups have a tolerance within 3%.
|
| |
| 24. |
Q. An acquaintance is bidding on a project which requires that his viscosity
measuring equipment complies to MIL STD 45662A.
What is this reference?
A. MIL STD 45662A is a document which sets forth very specifically the procedures that must be followed in the certification of many types of testing equipment to an industry
standard. Procedures that must be followed in certifying viscosity cups fall under this
document. It includes the requirement of periodic evaluation of master thermometers
and timing devices by the U.S. National Institute for Standards and Technology. It
even includes setting down the environmental conditions under which certification
procedures are conducted. It is the reason that standard viscous materials are used
which are traceable to the U.S. National Institute for Standards and Technology.
|
| |
| 25. |
Q. Is there a possibility that I would ever have to comply with
MIL STD 45662A?
A. If you ever contract with a government agency at any level and especially any arm of the Federal establishments, including the military, one of the requirements that
will probably be imposed is that your measuring equipment must be certified in
compliance with this document.
|
| |
| 26. |
Q. Do your viscosity cups qualify for certification under MIL STD 45662A?
A. Yes. Any viscosity cup produced by the Paul N. Gardner Company qualifies
for certification under MIL STD 45662A and such certification is available as
an extra cost service.
|
| |
| 27. |
Q. Just what is this certification - what would I get?
A. You would receive a certificate identifying you as the owner of a specific
viscosity cup which would also be identified. Qualification for and conditions
under certification would be listed. Actual results from the running of standard
oils in your cup would be listed. These results include the target drain time for
the oil used and the average from multiple drain time runs with your cup. The
difference, if any, between the target drain time and that for your cup is
included as a correction factor. The certificate is dated, signed by the
technician doing the work and by his supervisor.
|
| |
D. Cup Use
|
| 28. |
Q. Please outline for me the correct procedure for using a dip type
viscosity cup.
A. |
| |
- Insure that the product you are going to measure is at the specified
measuring temperature, is well mixed and is free of air bubbles and that
you have on hand the appropriate cup for the viscosity range in
question.
- Inspect the cup and insure that it is clean, giving particular attention to the
orifice area.
- Hold the ring at the top and immerse the cup in the material being
measured so that the top edge of the cup is about a half inch below the
liquid level.
- Quickly withdraw the cup from the test material and at the same time
start a timing device.
- Carefully observe the efflux stream and at the first distinct break in the
stream, one to two inches below the bottom of the cup, stop the timing
device.
- Record the number of seconds drain time, temperature at time of measurement as well as cup type and number.
- Use the Gardco Viscosity Conversion Chart that accompanies each cup and convert seconds efflux time to centistokes viscosity if desired.
|
| 29. |
Q. Why should I hold the cup by the ring rather than the wire loop?
A. The cup is held by the ring to insure that the cup is vertical during the drain period. If it is not so held, and is not vertical, the efflux stream will drift to
one side of the orifice and errors will result. (This answer does not apply to
the Ford Dip Cup where the orifice extends below the immediate surrounding
cup surface.)
|
| |
| 30. |
Q. What type of thermometer should I use to measure the temperature of the
test material?
A. Any type of thermometer that has rapid response and can be read to the
nearest tenth of a degree Celsius or the nearest two tenths of a degree Fahrenheit.
Where a high degree of accuracy is not required, bi-metallic thermometers
which can be read to the nearest 1/2 degree Celsius or (1°F) may be
used.
|
| |
| 31. |
Q. What type of a timer should I use to measure drain time?
A. Any type which will register to the nearest tenth second. The electronic digital
type, registering to the nearest 1/100 second is gaining in popularity.
|
| |
| 32. |
Q. Should I convert drain time seconds to centistokes in recording results?
A. It depends on the end use of your data. If it is for internal comparative use
only, such conversion may not be helpful. For any other purposes, it will
probably be advisable to make the conversion. It can always be made at a
later time.
|
| |
| 33. |
Q. Is it best to take averages of several readings?
A. Averaging several readings will reduce operator error. In all calibration and certification work at least three determinations are averaged.
|
| |
| 34. |
Q. What care should be taken of the cup following use?
A. It should be thoroughly cleaned unless it is to be immediately used to
repeat readings with the same material. In any case do not expose the cup to
air after use but place it back into the test material. Any drying of such
materials on the cup surfaces will cause errors in following determinations or
make the cup more difficult to clean. |
| |
E. Temperature Control
|
| 35. |
Q. I have been hearing more and more about the importance of temperature
control. Would you elaborate?
A. Most of the reported problems in viscosity measurement relate to failure
to control or to know the temperature of the material under question at time of
measurement. Many materials display a very large change in viscosity as a
function of relatively small change in temperature. A viscosity measurement
is simply not meaningful unless the temperature at time of measurement is also
known and recorded. Generally, the higher the viscosity the greater the change
with respect to temperature. As an example, the standard oils used for cup
calibration and certification change between 3% and 8% per degree Celsius,
depending on the viscosity of the standard at normal use temperature.
|
| |
| 36. |
Q. At what temperature should I make my measurements?
A. It is customary to make viscosity measurements at 25 degrees Celsius
which is 77 degrees Fahrenheit. However, measurements can be made at any
other agreed on temperature. In some processes it is just not practical to measure
at the customary temperature. But no matter what temperature is used it must be
stated along with the viscosity determination.
|
| |
| 37. |
Q. Is it important that the cup be at the same temperature as the product
prior to a measurement.
A. Yes. If it is not it will change the temperature of the product during the drain
time. It is therefore good practice to measure temperature in the efflux stream.
It is also good practice to place the cup in the material to be measured prior to
the determination to insure that they are both at the desired temperature.
Temperature control is easier if measurements are made in a draft free area
which is as near as possible the same temperature as that at which measurements
will be made.
|
| |
| 38. |
Q. Is there any way that I can adjust measured drain time for a particular
material to a target temperature?
A. Within limits, yes. This can be done if the temperature index of the material is known. The temperature index is the percent change in viscosity per degree
temperature in a given temperature range. The procedure for determining and
using the temperature index for a given material is described in the long form
product bulletins for viscosity cups produced by Gardco, the Paul N. Gardner
Company. |
| |
Addendum
|
| 39. |
Q. Can we try a viscosity cup and return it for a cup with another size orifice?
A. Our policy is that once a cup has been sold we cannot accept its return either for
credit or another size or type cup. Once a cup has been dipped into a material
it is not possible to clean it and restore it to the perfect, new condition as when
sold. Before ordering be sure you know what size orifice and which cup will suit
your needs.
|
| |
| 40. |
Q. Why shouldn’t I just report Zahn viscosity cup readings as seconds efflux time?
A. Remember that there are many different makes of Zahn cups out there that can
give you just as many different readings in seconds efflux time, so you can see
that only reporting in seconds can many times be unmeaningful and very
misleading.
As an example, 40.0 seconds efflux in one make cup is 60.8 seconds in another
make cup when measuring the same liquid at the same temperature. It is
important for you to not only record the seconds efflux time but also it is now
possible to determine the actual viscosity of the material by converting seconds
to centistokes viscosity using your Gardco Cup Conversion Table. Then you
have a meaningful basis of reference that can be relied on.
We recommend that you also include the cup maker’s name in your report as
well as temperature at time of test. As an example: 30.6 seconds, Gardco EZ Cup
#2, 61.3 centistokes viscosity @ 77° F (25° C). Now you have recorded
information that you can definitely rely on.
|
| |
| 41. |
Q. How can I convert centipoises to centistokes?
A. The centistoke is defined as the centipoise divided by density (or weight per
gallon times 0.120). To convert, you must know the density or weight per
gallon of the material. For example: you know the weight per gallon of the
material is 9.5. Multiply 9.5 times 0.120 to find its density. Now assume that
the material has a viscosity of 150 centipoises.
9.5 X 0.120 = 1.14
150 ÷ 1.14 = 132 centistokes.
centipoises ÷ (weight per gallon x 0.120) = centistokes
|
| |
| 42. |
Q. If I know the viscosity in centistokes (as an example is 132)and the weight
per gallon of the material (i.e. 9.5) how do I convert to centipoises
viscosity?
A. Centistokes X (weight per gallon x 0.120) = centipoises
132 X 1.14 = 150 centipoises
|
| |
| 43. |
Q. I am using two new EZ#2 cups and each gives a different reading. One
gives 17 seconds and the other is 20 seconds efflux time. Why are these
readings so far apart?
A. The cups are being used below the recommended 20 to 60 second range as
stated in the product leaflet for this instrument. There are good technical
reasons for the stated range of 20 to 60 seconds. A material approaching zero
viscosity will have an efflux time from the #2 cup of 16.3 seconds. Viscosity
of a material has very little influence on cup drain time when near this
minimum. Please note the following centistoke - drain time seconds relationship:
Centistokes Seconds Drain Time - EZ#2
0.00 16.3
3.66 17.0
18.65 20.0
You should be using the #1 EZ cup instead of the #2 EZ cup. It should also
be noted that if any of your work is below 10 centistokes the only cup type
instrument that can be recommended is the Ford cup with the #0 orifice.
|
| |
| 44. |
Q. My supplier tells me that I should buy a No. 2 Zahn Type Cup and my
lacquer should run through this cup orifice within 20-24 seconds. Do you
make such a cup?
A. Your supplier has not given you enough information to answer your
question. You should also know the makers name, shown on the nameplate.
There are many different makes of Zahn Cups out there that can give you as
many different readings which could lead to meaningless and misleading
results. If it is a No. 2 EZ Cup with a Gardco or Paul N. Gardner Company
nameplate you can then look at our No. 2 EZ Cup Conversion Grid which
accompanies every Gardco cup and in this instance you will note the chart
shows 20, 21, 22, 23 and 24 in the seconds column and the table shows that
the equivalent viscosity in centistokes is 18.7, 23.2, 27.6, 31.9 and 36.1
centistokes; you now have been able to convert seconds efflux time into
meaningful basic centistokes viscosity. With a Gardco made No. 2 EZ
viscosity cup you not only know the seconds efflux time but now you know
what the actual viscosity is in centistokes. You now have a solid foundation
on which your results can be expressed. To our knowledge you can’t do this
with any other make cups . |
| |