Site Map    Contact Us
Search Our Site

 

 

Krebs Unit Viscometer Model KU-2

DIGITAL DIRECT DISPLAY OF VISCOSITY IN KREBS UNITS

Measures Paints, Coatings And Related Materials

 

Krebs Unit Viscometer Model KU-2
  • Direct-reading LED display, all models
    • Krebs Units (KU)
    • Centipoise (cP)
    • Grams (gm)
    • Display output to parallel printer
  • Easy to use
    • No weights
    • Simplifies an established test technique
  • Used in
    • Quality control
    • Research and development
  • Specification References
    • ASTM D562
    • ASTM D856
    • ASTM D1131
    • International Specifications
  • Options
    • Air purge with electrical
      system interlock
    • Model KU-2 uses standard 1 pint can. Adapters are
      provided to accommodate 1/2 pint and quart cans.
 
 
 
 

 

 

SPECIFICATIONS
Range 40 to 141 KU; 32 to 1099 gm; 27 to 5,274 cP
Resolution Within 0.1 KU or 1 gm
Accuracy Within ±1% of full scale
Reproducibility Within ±0.5% of full scale
Operating temperature 10°C to 40°C
Spindle speed 200 rpm ±0.1rpm
Measuring containers 1 pint, 1/2 pint, 1 quart cans
Power line requirement 110 or 220 volts, 50 or 60 Hz
References ASTM D562, D856, D1131
Shipping weight 22 lbs. (10 kg)
Return to the Top of the Page...


VISCOSITY STANDARD OILS
VISCOSITY STANDARD VISCOSITY CENTIPOISE KREBS UNIT KU
VI-0280 400 64
VI-0281 750 79
VI-0282 940 84
VI-0283 1400 95
VI-0284 2000 106

 

 

OPERATION

Samples are tested in standard paint industry cans (1 pint, 1/2 pint, or 1 quart) held by a centering and retaining fixture. The container is filled to within 3/4" (20mm) of the top and located on the viscometer base

The operating lever has three positions:.

  Up Spindle stationary, drive motor off
  Down Spindle rotating, sample being measured

The displayed reading can be held by depressing the HOLD switch at any time. With the viscometer in the
HOLD configuration, the display may be switched to compare the Krebs (KU) or Centipoise (cP) reading
with the associated gram (gm) reading. If the spindle is stalled, no damage will result, as a torque-limiting
circuit protects the spindle drive.

For best reproducibility of sample measurements, the test material should be preconditioned for temperature and shear stability.

Please note:

 

 

available items
Item Number Item
VI-020102 Krebs Unit Viscometer - Standard Model, 115V
VI-020104 Krebs Unit Viscometer w/ Air Purge, 115V
VI-020112 Krebs Unit Viscometer - Standard Model, 230V
VI-020114 Krebs Unit Viscometer with Air Purge, 230V
TH-02280 Stormer ASTM 49C Thermometer (20-70°C x 0.2°)
TH-02280/C Stormer ASTM 49C Thermometer w/ NIST Certificate
Spindles
VI-0223 Krebs Replacement Spindle
VI-0225 Krebs Paste Spindle

 

 

Home   Viscosity   How To Order   Top Of The Page Paul N. Gardner Company, Inc. • Phone 1.800.762.2478 • Fax 954.946.9309