| Cone/Plate Viscometers |
 |
|
| Wells-Brookfield Digital Display Model |
 |
- cone/plate geometry generates defined shear rates
- indicates absolute viscosity in
centipoise (mPa•s)
- small sample volume (0.5 to 2ml)
- sample temperature precisely
measured and controlled
- wide selection of shear rates
|
| The Wells-Brookfield Cone/Plate Viscometer
gives researchers a sophisticated instrument for routinely determining absolute
viscosity of fluids in small sample volumes. Its cone and plate geometry provides the precision necessary for development
of complete rheological data. |
 |
The Wells-Brookfield Cone/Plate Viscometer is a precise torque meter which is driven at discrete rotational speeds. The torque measuring system, which consists of a calibrated beryllium-copper spring connecting the drive mechanism to a rotating cone, senses the resistance to rotation caused by the presence of sample fluid between the cone and a stationary flat plate.
The resistance to the rotation of the cone produces a torque that is proportional to the shear stress in the fluid. The amount of torque is indicated either on a dial or digital display,
depending on model. This reading is easily converted to absolute centipoise units (mPa.s) from precalculated range charts. Alternatively, viscosity can be calculated from the known geometric constants of the cone, the rate of rotation, and the stress related torque. |
 |
| Wells-Brookfield
Cone/Plate Viscometers |

|
Electronic Gap Setting Technology allows fast set-up time and minimizes the possibility of "gap" adjustment errors. A bright LED lights up when a "hit point" is achieved. A simple turn of the micrometer adjustment ring and the "gap" is set, reducing the time required associated with manual detection methods. The Electronic Gap Setting Technology is a standard feature on all of the Wells-Brookfield Cone/Plate Digital Viscometers/Rheometers.
The stationary plate forms the bottom of a sample cup which can be removed, filled with .5 mL to 2.0 mL of sample fluid (depending on cone in use), and remounted without disturbing the calibration. The sample cup is jacketed and has fittings for connection to a constant temperature circulating bath.
The system is accurate to within ±1.0% of the viscosity range. Repeatability is to within ±0.2%. Working temperature range is from 0°C to 100°C. |
Embedded Temperature Probe can be installed in sample cup for precise temperature measurement. REQUIRES TECHNICAL ASSISTANCE AS TO SPECIFIC APPLICATION.
Purge Fittings can be installed to maintain a controlled
atmosphere in the sample cup. Luer Fittings can be installed to allow sample material to be introduced without having to remove sample cup.
Luer Fittings can be installed to allow sample material
to be introduced without having to remove the sample cup.
Embedded Temperature Probe in cup for Cone/Plate Viscometer provides
accurate temperature measurement of sample during test. Also shown
are standard hose connections to constant temperature circulating fluid bath. |
 |
Cone/Plate Ranges - Centipoise (mPa•s)
|
LV Series Viscometers & Rheometers
|
| Cone Spindle* |
LVDV-I+ |
LVDV-II+** |
LVDV-III+ |
Shear Rate*** (sec-1) |
Sample Volume (mL) |
| CPE-40 |
CP-40 |
0.3 - 1,023 |
0.2 - 3,070 |
0.1 - 3,070 |
7.50N |
0.5 |
| CPE-41 |
CP-41 |
1.2 - 3,837 |
0.6 - 11,510 |
0.5 - 11,510
|
2.00N |
2.0 |
| CPE-42 |
CP-42 |
0.6 - 2,000 |
0.3 - 6,000 |
0.2 - 6,000 |
3.84N |
1.0 |
| CPE-51 |
CP-51 |
4.9 - 16,000 |
2.4 - 48,000 |
1.9 - 48,000 |
3.84N |
0.5 |
| CPE-52 |
CP-52 |
9.3 - 30,720 |
4.6 - 92,160 |
3.7 - 92,160 |
2.00N |
0.5 |
*CPE- refers to electronic gap adjustment, while CP- refers to manual gap adjustment
** Maximum viscosity range shown is at 0.1rpm
***N=rpm Example: RV Viscometer with CPE-42 spindle at 10rpm has shear rate 3.84 x 10=38.4 sec1 |
RV Series Viscometers & Rheometers |
| Cone Spindle* |
RVDV-I+ |
RVDV-II+** |
RVDV-III+ |
Shear Rate*** (sec-1) |
Sample Volume (mL) |
| CPE-40 |
CP-40 |
3.3 - 10,900 |
1.6 - 32,700 |
1.3 - 32,700 |
7.50N |
0.5 |
| CPE-41 |
CP-41 |
12.3 - 40,933 |
6.1 - 122,800 |
4.9 - 122,800 |
2.00N |
2.0 |
| CPE-42 |
CP-42 |
6.4 - 21,300 |
3.2 - 64,000 |
2.6 - 64,000 |
3.84N |
1.0 |
| CPE-51 |
CP-51 |
51.2 - 170,666 |
25.6 - 512,000 |
20.5 - 512,000 |
3.84N |
0.5 |
| CPE-52 |
CP-52 |
98.3 - 327,666 |
49.2 - 983,000 |
39.3 - 983,000 |
2.00N |
0.5 |
*CPE- refers to electronic gap adjustment, while CP- refers to manual gap adjustment
** Maximum viscosity range shown is at 0.1rpm
***N=rpm Example: RV Viscometer with CPE-42 spindle at 10rpm has shear rate 3.84 x 10=38.4 sec1 |
HA Series Viscometers & Rheometers |
| Cone Spindle* |
HADV-I+ |
HADV-II+** |
HADV-III+ |
Shear Rate*** (sec-1) |
Sample Volume (mL) |
| CPE-40 |
CP-40 |
6.6 - 21,800 |
3.3 - 65,400 |
2.6 - 65,400 |
7.50N |
0.5 |
| CPE-41 |
CP-41 |
24.6 - 81,866 |
12.3 - 245,600 |
9.8 - 245,600 |
2.00N |
2.0 |
| CPE-42 |
CP-42 |
12.8 - 42,600 |
6.4 - 128,000 |
5.1 - 128,000 |
3.84N |
1.0 |
| CPE-51 |
CP-51 |
102.4 - 341,333 |
51.2 - 1,024,000 |
41.0 - 1,024,000 |
3.84N |
0.5 |
| CPE-52 |
CP-52 |
196.6 - 655,333 |
98.3 - 1,966,000 |
78.6 - 1,966,000 |
2.00N |
0.5 |
*CPE- refers to electronic gap adjustment, while CP- refers to manual gap adjustment
** Maximum viscosity range shown is at 0.1rpm
***N=rpm Example: RV Viscometer with CPE-42 spindle at 10rpm has shear rate 3.84 x 10=38.4 sec1 |
HB Series Viscometers & Rheometers |
| Cone Spindle* |
HBDV-I+ |
HBDV-II+** |
HBDV-III+ |
Shear Rate*** (sec-1) |
Sample Volume (mL) |
| CPE-40 |
CP-40 |
26.2 - 87,200 |
13.1 - 261,600 |
10.5 - 261,600 |
7.50N |
0.5 |
| CPE-41 |
CP-41 |
98.3 - 327,466 |
49.1 - 982,400 |
39.3 - 982,400 |
2.00N |
2.0 |
| CPE-42 |
CP-42 |
51.2 - 170,666 |
25.6 - 512,000 |
20.5 - 512,000 |
3.84N |
1.0 |
| CPE-51 |
CP-51 |
409.6 - 1,365,333 |
204.8 - 4,096,000 |
163.8 - 4,096,000 |
3.84N |
0.5 |
| CPE-52 |
CP-52 |
786.4 - 2,621,333 |
393.2 - 7,864,000 |
314.6 - 7,864,000 |
2.00N |
0.5 |
*CPE- refers to electronic gap adjustment, while CP- refers to manual gap adjustment
** Maximum viscosity range shown is at 0.1rpm
***N=rpm Example: RV Viscometer with CPE-42 spindle at 10rpm has shear rate 3.84 x 10=38.4 sec1 |
Various cone spindles are available for use with Wells-Brookfield Cone/Plate instruments. One cone spindle is provided with the instrument & is calibrated for use with the same cup.
Additional cone spindles may be purchased and will be calibrated for use with the sample cup. |
| Cone Spindle Dimensions |
| Cone Spindle |
Angle (deg.) |
Radius (cm) |
| CP-40 or CPE-40 |
0.80 |
2.4 |
| CP-14 or CPE-41 |
3.0 |
2.4 |
| CP-42 or CPE-42 |
1.565 |
2.4 |
| CP-51 or CPE-51 |
1.565 |
1.2 |
| CP-52 or CPE-52 |
3.0 |
1.2 |
|

Optional embedded temperature probe (shown with Luer and Purge fittings.) |
 |
 |
Prices subject to change Prices listed in US dollars for domestic shipments within US, Canada, & Mexico only Export orders require quotations - click here for a quote For more info call us 1-800-762-2478 or 954-946-9454. |
|
| Item Number |
Item |
Prices |
Wells-Brookfield Cone & Plate (C/P) Viscometers |
| Programmable Rheometer (1, 3) |
DV-III Ultra LV/RV/HA/HB (8) |
$5,355.00 |
| Programmable Viscometer (1, 2, 3) |
DV-II+ Pro LV/RV/HA/HB |
4,195.00 |
| Digital Viscometer (3, 4, 5) |
DV-I Prime LV/RV/HA/HB |
3,575.00 |
| Options |
| (1) Optional Rheocalc Software without cable add |
770.00 |
| (2) Optional Wingather Software without cable add |
440.00 |
| (3) With Temperature Probe in Sample Cup add |
210.00 |
| (4) With optional RTD Temperature Probe add |
310.00 |
| (5) Optional Wingather software with cable add |
490.00 |
| (8) Ball bearing suspension not available in LV torque |
|
 |
|