Rapid Flash Point Tester

 

The Rapid Tester® is a semiautomatic instrument for determining the flash point temperature / combustibility of flammable liquids. Closed cup test temperatures from ambient to 572°F (300°C) are automatically controlled by the set-a-temp adjustable digitally preset target temperature circuitry. Integral digital LCD display, NIST traceable thermometer, disposable fuel tank and electronic timer are standard.

 

Rapid Flash Point Tester

 

In accordance with:
ASTM D 3278 BS 3900 Part A14 ISO 3679
ASTM D 3828 CPSC CFR 16-1500.43a ISO 3680
ASTM D 4206 DOT CFR 49-173.115 OSHA 29CFR 1910-106
BS 3900 Part A11 IATA Resolution 618 Attachment A OSHA 29CFR 1910-1200
BS 3900 Part A13 IP 303  

 

Quality Assurance
 

Verify the formulation of liquid products with flammable ingredients.

 

Compliance Testing
 

Often required by regulatory agencies before transport or disposal of liquids

 

Fuel Dilution
  Determine the relative percentage of fuel in engine crank case oil to forecast the need for engine rebuilding.

 

 

Digital Accuracy


Achieve the high level of digital performance offered only by the Rapid Tester®. The high contrast LCD display has 1/2" characters for ease of reading and is switch selectable between degrees Fahrenheit and Centigrade. A thermometer traceable to the National Institute of Standards & Technology is also included.

Unique set-a-temp circuitry permits simple adjustment and precise automatic regulation of test temperatures. Depress the Preset switch while turning the Temperature Control knob until the target temperature is displayed. Release the switch and set-a-temp takes over! Test cup temperature is automatically shown on the digital LCD display.

 

 

Fast Test-Small Sample

Test time is only one minute with a 2 ml sample for flash points below 212°F (100°C). You can run ten tests with the Rapid Tester® in the time that it takes to perform just one by other methods. The 2 ml/4 ml sample is a fraction of the large sample required by other flash point methods. This reduces sampling and disposal problems while improving safety.

Two Models

The Rapid Tester® Closed Cup Model RT-01 has a testing range from -22° to 572°F (-30° to 300°C). Open Cup Model RT-02 tests for flash point levels from ambient to 212°F (100°C).

Compare Results

Independent laboratory testing has demonstrated that the ASTM D 3828 test method utilized by the Rapid Tester® correlates well with other flash point methods. In ASTM D-2 Round Robin testing it was found that the ASTM D 3828 test method has the following correlation coefficients:

D 3828 (Rapid Tester®) vs. D 56 (Tag) = 0.9949
D 3828 (Rapid Tester® vs. D 93 (Pensky-Martens) = 0.9943
D 56 vs. D 93 = 0.9926

With better than 99% comparability you can use the Rapid Tester® with confidence.

 

 

Characteristics

Performance (RT-01)
Repeatability 0.5° @ 70°C
2.0° @ 150°C
Reproducibility: 2.0° @ 70°C
7.5° @ 150°C
Test Time: 1 min below 212°F
2 min above 212°F (100°C)
Physical
Cup Type: RT-01 Closed
RT-02 Open
Cup Material: Aluminum    (316ss optional)
Dimensions: 15.0 x 3.4 x 6.3"
(38.1 x 8.64 x 16.25cm)
Display: LCD digital and NIST traceable mercury-in-glass thermometer
Net Weight: 10 lbs (4.6 Kg)
Power Requirements: 115/230V, 50/60 Hz
Sample Size: RT-01 2 ml below 212°F
4 ml above 212°F (100°C)
RT-02 2 ml
Temperature Range: RT-01 -22° to 572°F    (-30° to 300°C)
RT-02 Ambient to 212°F (100°C)


Warranty

 

Rapid Tester instrumentation is warranted against defects in materials and workmanship for one year from date of shipment and will be repaired or replaced at our option. This warranty is exclusive of shipping charges, consumable components or misuse. The liability of Gardco is limited to such repair or replacement. No warranty of fitness for a particular purpose or liability for consequential or other damages shall be implied.

 

 

Available Items
Item Number Item
FP-1000 Rapid Tester®, Closed Cup, -22° to 572°F (-30° to 300°C) Aluminum Test Cup/Brass Lid & Shutter
FP-1000/SS Rapid Tester®, Closed Cup, -22° to 572°F (-30° to 300°C) 316ss Test Cup/316ss Lid & Shutter
FP-1100 Rapid Tester®, Open Cup, Ambient to 212°F (100°C) Aluminum Test Cup
FP-1100/SS Rapid Tester®, Open Cup, Ambient to 212°F (100°C) 316 Stainless Steel Test Cup
Accessories
FP-1720 316 SS Lid & Shutter assembly replacement
FP-1660 316 SS Cup assembly replacement
FP-1740 Standard Brass Lid & Shutter Assembly Replacement
FP-1670 Heat Transfer Compound
FP-1680 Metal Cooling Block
FP-1690 Refrigerant Charged Cooling
FP-1710 Syringe 2ml / 4ml
FP-1730 Fuel Cylinder
FP-1750 Gasket
FP-1760 Valve Assembly
Thermometers (Traceable to N.I.S.T)
FP-1810 32° to 572°F (0° to 300°C)
FP-1820 32° to 230°F
FP-1830 0° to 110°C
FP-1840 -36° to 105°F
FP-1850 -38° to 40°C
FP-1860 212° to 572°F
FP-1870 100° to 300°C
ASTM Flashpoint Standards
FP-1981 ASTM D 56 @ 50°C, ASTM D 93 @ 55°C (200ml)
FP-1983 ASTM D 56 @ 66°C, ASTM D 92 @ 79°C, ASTM D 93 @ 72°C (200ml)
FP-1985 ASTM D 92 @ 116°C, ASTM D 93 @ 113°C (200ml)
FP-1987 ASTM D 92 @ 137°C, ASTM D 93 @ 132°C (200ml)
FP-1989 ASTM D 92 @ 163°C, ASTM D 93 @ 155°C (200ml)
FP-1991 ASTM D 92 @ 224°C, ASTM D 93 @ 218°C (200ml)

 

Note: This leaflet contains only a general description of the Rapid Flash Point Tester. While uses and performance capabilities are described, under no circumstances should the product be used except by qualified, trained personnel and not until the instructions, labels, or other literature accompanying it have been carefully read and understood and the precautions therein set forth followed. Only they contain the complete and detailed information concerning this product. Not intended for use in hazardous areas. The manufacturer reserves the right to alter design and/or specifications without notice.

 

 

Home   Lab Apparatus     How To Order   |Top Of The Page Paul N. Gardner Company, Inc. • Phone 1.800.762.2478 • Fax 954.946.9309